156
upper
-
value
: Upper temperature limit in Celsius degrees. The value ranges from 20 to
90.
The
upper-value
argument must be larger than the
lower-value
argument.
Description
Use the
temperature
-
limit
command to set the temperature alarm threshold on a
board.
Use the
undo
temperature
-
limit
command to restore the temperature alarm threshold
to the default.
By default, the temperature alarm threshold depends on your AC model.
NOTE:
The
upper-value
argument must be bigger than the
lower-level
argument.
Support for this command depends on your AC model.
Examples
Set the lower temperature limit on board 1 to 10 Celsius degrees and the upper
temperature limit to 75 Celsius degrees.
<Sysname> system-view
[Sysname] temperature-limit 1 10 75
Setting temperature limit succeeded.
time
Syntax
time
timeID
at
time1 date
command
command
time
timeID
{
one-off
|
repeating
}
at
time1
[
month-date
month-day
|
week-day
week-daylist
]
command
command
time
timeID
{
one-off
|
repeating
}
delay
time2
command
command
undo
time
timeID
View
Job view
Default Level
3: Manage level
Parameters
timeID
:
Time index, an integer ranging from 1 to 10.