![Grundig GD-RT-AC3004N User Manual Download Page 111](http://html1.mh-extra.com/html/grundig/gd-rt-ac3004n/gd-rt-ac3004n_user-manual_2272749111.webp)
111 ENGLISH
8.2 Setting Sensor Alarms
Set up the handling method of an external sensor alarm.
Steps:
1.
Go to
Menu > Configuration > Alarm > Alarm Input
.
Alarm Input Settings Interface
2.
Set the handling method of the selected alarm input.
Check the <Enable> checkbox and click
to set its alarm response actions.
Set Arming Schedule of Alarm Input
3.
Select the <Trigger Channel> tab and select one or more channels which will start to record or
start full-screen monitoring when an external alarm input is triggered.
4.
Select the <Arming Schedule> tab to set the channel’s arming schedule.
Select one day of a week and a maximum of eight time periods can be set within each day.
Note:
Time periods shall not be repeated or overlapped.
5.
Select
the <Linkage Action>
tab to set up alarm response actions of the alarm input (Refer to
Chapter 8.7 Setting Alarm Response Actions
).
Repeat the above steps to set up an arming schedule for other days of a week. You can also
use the <Copy> button to copy an arming schedule to other days.