GREE GMV5 HR HEAT RECOVERY UNITS
327
Project name
Unit model
Debugged by
Date
ODU rated capacity
(kW)
General IDU rated
capacity (kW)
Total length of refrigerant
pipes (m)
Maximum fall of IDUs
(m)
Fill amount of refrigerant (kg)
Debug state: Refrigerating Heating Number and capacity of running IDUs
State parameter
Unit
Prestart
30min
60min
90min
System temperature
under low pressure
°F
1# IDU
Rated capacity
kW
Ambient temperature
°F
IDU gear
Gear
Outlet temperature
°F
Outlet speed
M/S
Noise
dB
Water tray
——
2# IDU
Rated capacity
kW
Ambient temperature
°F
IDU gear
Gear
Outlet temperature
°F
Outlet speed
M/S
Noise
dB
Water tray
——
4 COMMON PARAMETER LISTS
4.1 R410A refrigerant pressure / saturation temperature list
Temperature
Corresponding
saturation pressure
Temperature
Corresponding
saturation pressure
Temperature
Corresponding
saturation pressure
°C
°
F
BAR
psi
°C
°
F
BAR
psi
°C
°
F
BAR
psi
-43
-45.4
1.54
22.34
-9
15.8
5.97
86.59
25
77.0
16.64
241.34
-42
-43.6
1.61
23.35
-8
17.6
6.18
89.63
26
78.8
17.08
247.72
-41
-41.8
1.68
24.37
-7
19.4
6.39
92.68
27
80.6
17.54
254.40
-40
-40.0
1.76
25.53
-6
21.2
6.61
95.87
28
82.4
18.01
261.21
-39
-38.2
1.84
26.69
-5
23.0
6.84
99.21
29
84.2
18.48
268.03
-38
-36.4
1.93
27.99
-4
24.8
7.07
102.54
30
86.0
18.97
275.14
-37
-34.6
2.02
29.30
-3
26.6
7.30
105.88
31
87.8
19.46
282.24
-36
-32.8
2.11
30.60
-2
28.4
7.54
109.36
32
89.6
19.96
289.50
-35
-31.0
2.20
31.91
-1
30.2
7.79
112.98
33
91.4
20.48
297.04
-34
-29.2
2.30
33.36
0
32.0
8.04
116.61
34
93.2
21.00
304.58
-33
-27.4
2.40
34.81
1
33.8
8.30
120.38
35
95.0
21.53
312.27
-32
-25.6
2.50
36.26
2
35.6
8.57
124.30
36
96.8
22.08
320.24
-31
-23.8
2.61
37.85
3
37.4
8.84
128.21
37
98.6
22.63
328.22
-30
-22.0
2.72
39.45
4
39.2
9.12
132.27
38
100.4
23.20
336.49
-29
-20.2
2.83
41.05
5
41.0
9.40
136.34
39
102.2
23.77
344.75
-28
-18.4
2.95
42.79
6
42.8
9.69
140.54
40
104.0
24.36
353.31
-27
-16.6
3.07
44.53
7
44.6
9.99
144.89
41
105.8
24.95
361.87
-26
-14.8
3.19
46.27
8
46.4
10.30
149.39
42
107.6
25.56
370.72
Summary of Contents for GC201808-III
Page 87: ...GREE GMV5 HR HEAT RECOVERY UNITS 83 1 External Connection for Individual Units ...
Page 92: ...GREE GMV5 HR HEAT RECOVERY UNITS 88 ...
Page 227: ...GREE GMV5 HR HEAT RECOVERY UNITS 223 Troubleshooting ...
Page 286: ...GREE GMV5 HR HEAT RECOVERY UNITS 282 Troubleshooting ...
Page 362: ...JF00302879 ...