background image

LUNA

119RV46

MANUALE 

D’INSTALLAZIONE

SIRENA A LED PER CENTRALI ANTIFURTO

Italiano

IT

Русский

RU

Français

FR

English

EN

Italiano

IT

Summary of Contents for LUNA

Page 1: ...LUNA 119RV46 MANUALE D INSTALLAZIONE SIRENA A LED PER CENTRALI ANTIFURTO Italiano IT RU Fran ais FR English EN Italiano IT...

Page 2: ...simbolo indica parti riguardanti la sicurezza Questo simbolo indica cosa comunicare all utente La sirena LUNA stata progettata per centrali antifurto e viene installata esternamente Ogni installazion...

Page 3: ...ualsiasi momento e senza obbligo di preavviso IT Dati tecnici Alimentazione 12 V 15 V DC Assorbimento 1 5 A Assorbimento a riposo 30 mA Cono 8 magnetodinamico Livello pressione sonora 108 dB A ad 1 m...

Page 4: ...ligo di preavviso Pag 4 4 Codice manuale 119RV46 119RV46 ver 2 0 2 0 11 2012 CAME cancelli automatici S p A IT Dimensioni mm Componenti principali 1 Base sirena 2 Tamper antistrappo 3 Scheda elettroni...

Page 5: ...icie Verificare che le eventuali connessioni interne al contenitore eseguite per la continuit del circuito di protezione siano provviste di isolamento supplementare rispetto ad altre parti conduttrici...

Page 6: ...qu es ta are a la su pe rfic ie sia so lida e pia na tal e da off rire ap po gg io al pe rno di co nta tto de lla rin en a Co ntr olla re ch e in qu es ta are a la su pe rfic ie sia so lida e pia na...

Page 7: ...in questo manuale sono da ritenersi suscettibili di modifica in qualsiasi momento e senza obbligo di preavviso IT Togliere il coperchio della sirena svitando la vite posizionata frontalmente Togliere...

Page 8: ...to e senza obbligo di preavviso Pag 8 8 Codice manuale 119RV46 119RV46 ver 2 0 2 0 11 2012 CAME cancelli automatici S p A IT Forare sulla parte superiore della base in uno o pi punti a seconda del num...

Page 9: ...i di modifica in qualsiasi momento e senza obbligo di preavviso IT Controllare che la superficie di appoggio del fondo della sirena sia piana in modo da non compromettere il corretto funzionamento del...

Page 10: ...ale 119RV46 119RV46 ver 2 0 2 0 11 2012 CAME cancelli automatici S p A IT Inserire la batteria non inclusa nel fondo della sirena eseguire i collegamenti elettrici vedi capitolo cablaggi e i settaggi...

Page 11: ...celli automatici S p A I dati e le informazioni indicate in questo manuale sono da ritenersi suscettibili di modifica in qualsiasi momento e senza obbligo di preavviso IT Inserire e fissare la griglia...

Page 12: ...0 11 2012 CAME cancelli automatici S p A IT Descrizione scheda 1 Connettore per cavi batteria e cono 2 Interruttore antistrappo e antischiuma 3 Interruttore antiapertura 4 Connettore per cavi LED di...

Page 13: ...attivata dalla centrale 2 Default ON i LED lampeggiano fino al tempo di allarme impostato OFF i led lampeggiano fino al ripristino del comando sul morsetto C contatto N C 3 4 Impostazione del tempo d...

Page 14: ...stessa linea sequenziali il dimensionamento a tabella deve essere riconsiderato sulla base degli assorbimenti e delle distanze effettivi Per i collegamenti di prodotti non contemplati in questo manua...

Page 15: ...itenersi suscettibili di modifica in qualsiasi momento e senza obbligo di preavviso IT Alimentazione scheda e accessori necessari Batteria 12V DC 2 2Ah TAMPER Collegamento agli interruttori tamper C I...

Page 16: ...zioni opzionali LED1 Ingresso per comando LED posizionati frontalmente Un negativo collegato all ingresso i LED si accendono LED2 Ingresso per comando LED posizionati in basso Un negativo collegato al...

Page 17: ...ver 2 0 2 0 11 2012 CAME cancelli automatici S p A I dati e le informazioni indicate in questo manuale sono da ritenersi suscettibili di modifica in qualsiasi momento e senza obbligo di preavviso IT B...

Page 18: ...18 18 Codice manuale 119RV46 119RV46 ver 2 0 2 0 11 2012 CAME cancelli automatici S p A IT N B se si desidera che i LED1 e o LED2 si accendono dopo un comando di attivazione del sistema di allarme dop...

Page 19: ...ono assimilabili ai rifiuti solidi urbani e possono essere smaltiti sen za alcuna difficolt semplicemente effettuando la raccolta differenziata per il riciclaggio Prima di procedere sempre opportuno v...

Page 20: ...utomation Solutions Pvt Ltd New Delhi New Delhi 91 11 64640255 256 91 2678 3510 CAME Americas Automation Llc CAME Americas Automation Llc U S A Medley Medley FL 1 305 433 3307 1 305 396 3331 ASIA CAME...

Page 21: ...LUNA INSTALLATION MANUAL LED SIREN FOR BURGLARPROOF CONTROL UNITS English EN 119RV46EN...

Page 22: ...eans the parts describe safety issues This symbol tells you what to tell the user The LUNA siren is designed for burglarproof control units and is installed externally Every installation and use other...

Page 23: ...hout prior notice EN Technical data Power supply 12 V 15 V DC Power draw 1 5 A Power draw when idle 30 mA Cone 8 dynamic magnet Level of sound pressure 108 dB A ad 1 m Battery 12V 2 2 Ah Weight batter...

Page 24: ...r notice p 4 4 Manual code 119PV89 119PV89 ver 3 0 3 0 06 2012 CAME Cancelli Automatici S p A EN Dimensions mm Main component parts 1 Siren base 2 Rip proof tamper switch 3 Electronic card 4 Support f...

Page 25: ...tc Check that any connections inside the container made for continuity purposes of the protective circuit be fitted with extra insulation compared to other internal conductive parts Set up proper cond...

Page 26: ...pe rno di co nta tto de lla rin en a Co ntr olla re ch e in qu es ta are a la su pe rfic ie sia so lida e pia na tal e da off rire ap po gg io al pe rno di co nta tto de lla rin en a Co ntr olla re ch...

Page 27: ...The data and information in this manual may be changed at any time and without prior notice EN Remove the siren cover by unscrewing the front screw Remove the protective grille from the back of the si...

Page 28: ...t prior notice p 8 8 Manual code 119PV89 119PV89 ver 3 0 3 0 06 2012 CAME Cancelli Automatici S p A EN Perforate the top part of the base depending on the number of cables you have to pass through whe...

Page 29: ...may be changed at any time and without prior notice EN Check that the resting surface at the bottom of the siren is flat so as not to compromise the proper functioning of the Rip proof tamper Rip pro...

Page 30: ...2 CAME Cancelli Automatici S p A EN Insert battery not included into the bottom of the siren make any electrical connections see wiring chapter and necessary settings see function selection paragraph...

Page 31: ...r 2 0 2 0 11 2012 CAME Cancelli Automatici S p A The data and information in this manual may be changed at any time and without prior notice EN Insert and secure the protective grill using the 4 screw...

Page 32: ...Cancelli Automatici S p A EN Card description 1 Connector for battery cables and cone 2 Rip proof and foam proof switch 3 Open proof switch 4 LED warning lights cable connector 5 Dip switches 6 Power...

Page 33: ...control unit 2 Default ON the LEDs flash until the set alarm time OFF the LEDs flash until the N C contact command on terminal C is restored 3 4 Setting the siren alarm time see table ABOVE 5 6 Defaul...

Page 34: ...ntial ones the dimensions shown on the table must be reconsidered according to the total draw and actual distances When connecting products not featured in this manual only refer to the literature acc...

Page 35: ...manual may be changed at any time and without prior notice EN Power supply to card and accessories required Battery 12V DC 2 2Ah TAMPER Connection to tamper switches C Siren command input A positive...

Page 36: ...input for LE Ds positionedfrontally With a negative connected to the input the LEDs turn on LED 2 Command input for LEDs positioned below With a negative connected to the input the LEDs turn on Card...

Page 37: ...Manual code 119RV46 119RV46 ver 2 0 2 0 11 2012 CAME Cancelli Automatici S p A The data and information in this manual may be changed at any time and without prior notice EN External siren block with...

Page 38: ...8 18 Manual code 119PV89 119PV89 ver 3 0 3 0 06 2012 CAME Cancelli Automatici S p A EN N B if you wish LED 1 and or LED 2 to turn on after each alarm system activation com mand or motion detection in...

Page 39: ...of the packaging i e cardboard plastic etc are solid urban waste and may be disposed of without much trouble simply by separating them for recycling Before proceeding it is always a good idea to chec...

Page 40: ...Ltd CAME India Automation Solutions Pvt Ltd New Delhi New Delhi 91 11 64640255 256 91 2678 3510 CAME Americas Automation Llc CAME Americas Automation Llc U S A Medley Medley FL 1 305 433 3307 1 305 3...

Page 41: ...LUNA MANUEL D INSTALLATION SIR NE A LED POUR CENTRALES ANTIVOL Fran ais FR 119RV46FR...

Page 42: ...tion Ce symbole indique les parties concernant la s curit Ce symbole indique ce qu il faut communiquer l utilisateur La sir ne LUNA a t con ue pour des centrales antivol et est install e en externe To...

Page 43: ...tout moment et sans aucun pr avis FR Donn es techniques Alimentation 12 V 15 V DC Absorption 1 5 A Absorption au repos 30 mA C ne 8 magn todynamique Niveau de pression sonore 108 dB A 1 m Batterie 12...

Page 44: ...s aucun pr avis Page 4 4 Code manuel 119RV46 119RV46 ver 2 0 0 11 2012 CAME cancelli automatici S p A FR Dimensions mm Principaux composants 1 Base sir ne 2 Dispositif anti arrachement 3 Carte lectron...

Page 45: ...entuelles connexions internes au conteneur effectu es pour assurer la continuit du circuit de protection sont bien quip es d une isolation suppl mentaire par rapport aux autres parties conductrices in...

Page 46: ...h e in qu es ta are a la su pe rfic ie sia so lida e pia na tal e da off rire ap po gg io al pe rno di co nta tto de lla rin en a Co ntr olla re ch e in qu es ta are a la su pe rfic ie sia so lida e p...

Page 47: ...tenues dans ce manuel sont susceptibles de subir des modifications tout moment et sans aucun pr avis FR Retirer le couvercle de la sir ne en d vissant la vis positionn e frontalement Retirer la grille...

Page 48: ...aucun pr avis Page 8 8 Code manuel 119RV46 119RV46 ver 2 0 0 11 2012 CAME cancelli automatici S p A FR Forer sur la partie sup rieure de la base sur un ou plusieurs des points en fonction du nombre de...

Page 49: ...modifications tout moment et sans aucun pr avis FR Contr ler que la surface d appui du fond de la sir ne est bien plane de mani re ne pas risquer de compromettre le bon fonctionnement du dispositif a...

Page 50: ...ver 2 0 0 11 2012 CAME cancelli automatici S p A FR Mettre la batterie non fournie dans le fond de la sir ne effectuer les branchements lectriques voir chapitre c blages et les r glages voir paragrap...

Page 51: ...cancelli automatici S p A Les donn es et les informations contenues dans ce manuel sont susceptibles de subir des modifications tout moment et sans aucun pr avis FR Installer et fixer la grille de pro...

Page 52: ...cancelli automatici S p A FR Description carte 1 Connecteur pour c bles batterie et c ne 2 Interrupteur anti arrachement et anti mousse 3 Interrupteur anti ouverture 4 Connecteur pour c bles LED de s...

Page 53: ...2 D faut ON les LED clignotent jusqu l coulement de la dur e d alarme configur e OFF les leds clignotent jusqu la reprise de la commande sur le bornier C contact N C 3 4 Configuration de la dur e d a...

Page 54: ...e ligne s quentiels la dimension mentionn e dans le tableau doit tre revue sur la base des absorptions et des distances effectives Pour brancher des produits non pr vus dans ce manuel se r f rer la do...

Page 55: ...usceptibles de subir des modifications tout moment et sans aucun pr avis FR Alimentation carte et accessoires n cessaires Batterie 12 V CC 2 2 Ah S CURIT Branchement sur les interrupteurs de s curit C...

Page 56: ...s en option LED1 Entr e pour commande LEDS positionn s frontalement Un n gatif branch sur l entr e les LED s allument LED2 Entr e pour commande LED positionn s en bas Un n gatif branch sur l entr e le...

Page 57: ...19RV46 ver 2 0 0 11 2012 CAME cancelli automatici S p A Les donn es et les informations contenues dans ce manuel sont susceptibles de subir des modifications tout moment et sans aucun pr avis FR Bloc...

Page 58: ...18 Code manuel 119RV46 119RV46 ver 2 0 0 11 2012 CAME cancelli automatici S p A FR N B si on d sire que les LED1 et ou LED2 s allument sur une commande d activation du syst me d alarme apr s la d tect...

Page 59: ...lides et peuvent tre limin s sans aucune difficult simplement en proc dant au recueil diff renci pour le recyclage Avant d effectuer ces op rations il est toujours recommand de v rifier les normes sp...

Page 60: ...ation Solutions Pvt Ltd New Delhi New Delhi 91 11 64640255 256 91 2678 3510 CAME Americas Automation Llc CAME Americas Automation Llc U S A Medley Medley FL 1 305 433 3307 1 305 396 3331 ASIA CAME Asi...

Page 61: ...LUNA RU 119RV46RU...

Page 62: ...2 2 119RV46 119RV46 ver 2 0 2 0 11 2012 CAME cancelli automatici S p A RU LUNA LUNA CAME Cancelli Automatici S p A EN 50130 4 EN 50131 4...

Page 63: ...3 3 119RV46 119RV46 ver 2 0 2 0 11 2012 CAME cancelli automatici S p A RU 12 15 1 5 A 30 8 108 A 1 12 2 2 2 5 25 C 55 C 25 75 IP44 III 2...

Page 64: ...280 140 135 7 4 1 6 8 9 5 2 10 3 6 11 4 4 119RV46 119RV46 ver 2 0 2 0 11 2012 CAME cancelli automatici S p A RU 1 2 3 4 5 6 7 8 9 10 11...

Page 65: ...5 5 119RV46 119RV46 ver 2 0 2 0 11 2012 CAME cancelli automatici S p A RU...

Page 66: ...a off rire ap po gg io al pe rno di co nta tto de lla rin en a UP DOWN Co ntr olla re ch e in qu es ta are a la su pe rfic ie sia so lida e pia na tal e da off rire ap po gg io al pe rno di co nta tto...

Page 67: ...2 3 1 7 7 119RV46 119RV46 ver 2 0 2 0 11 2012 CAME cancelli automatici S p A RU 4...

Page 68: ...8 8 119RV46 119RV46 ver 2 0 2 0 11 2012 CAME cancelli automatici S p A RU...

Page 69: ...9 9 119RV46 119RV46 ver 2 0 2 0 11 2012 CAME cancelli automatici S p A RU...

Page 70: ...12V 2 2Ah 10 10 119RV46 119RV46 ver 2 0 2 0 11 2012 CAME cancelli automatici S p A RU dip 1 LOCK ON dip 1 LOCK OFF...

Page 71: ...1 2 3 11 11 119RV46 119RV46 ver 2 0 2 0 11 2012 CAME cancelli automatici S p A RU 4...

Page 72: ...7 8 6 5 1 2 4 3 9 12 12 119RV46 119RV46 ver 2 0 2 0 11 2012 CAME cancelli automatici S p A RU 1 2 3 4 5 Dip 6 7 F 3 15 A 8 F 3 15 A 9...

Page 73: ...9RV46 119RV46 ver 2 0 2 0 11 2012 CAME cancelli automatici S p A RU 1 ON OFF 30 2 ON OFF C 3 4 5 6 5 OFF 6 ON LED 1 7 8 7 OFF 8 ON LED 2 dip 3 4 3 OFF 4 OFF 600 3 ON 4 OFF 420 3 OFF 4 ON 180 3 ON 4 ON...

Page 74: ...ncelli automatici S p A RU CEI EN 60204 1 1 10 10 20 20 30 FROR CEI 20 22 CEI EN 5 0 2 6 7 2 1 2 x 0 5 2 2 x 0 75 2 2 x 1 0 2 2 x 0 22 2 2 x 0 5 2 2 x 0 5 2 1 x 0 22 2 1 x 0 5 2 1 x 0 5 2 2 x 0 22 2 2...

Page 75: ...15 15 119RV46 119RV46 ver 2 0 2 0 11 2012 CAME cancelli automatici S p A RU 12 2 2 TAMPER C C C 12...

Page 76: ...16 16 119RV46 119RV46 ver 2 0 2 0 11 2012 CAME cancelli automatici S p A RU LED1 LED2 LOCK LOCK 30 LOCK...

Page 77: ...CENTRAL 17 17 119RV46 119RV46 ver 2 0 2 0 11 2012 CAME cancelli automatici S p A RU...

Page 78: ...LED1 LED2 18 18 119RV46 119RV46 ver 2 0 2 0 11 2012 CAME cancelli automatici S p A RU LED1 LED2 LED1 LED2...

Page 79: ...19 19 119RV46 119RV46 ver 2 0 2 0 11 2012 CAME cancelli automatici S p A RU CAMECANCELLIAUTOMATICIS p A UNI EN ISO 14001...

Page 80: ...nes Lessines 32 68 333014 32 68 338019 INDIA CAME India Automation Solutions Pvt Ltd CAME India Automation Solutions Pvt Ltd New Delhi New Delhi 91 11 64640255 256 91 2678 3510 CAME Americas Automatio...

Reviews: