With the handset lifted:
If programming the telephone as master, replace the handset.
If programming it as slave, press the door release push button, then replace the
handset.
IMPORTANT:
If the installation has a CD-PLUS/R5 converter with coded door panel or guard unit, the programming codes assigned to
the telephones must be between 1 and 250. To make it easier for the user to make a call, another parallel code can be
assigned in a 2nd assignment table.
From sound module:
Locate the DIP switch situated at the back of the sound module and set number 2 to ON, as
described on p. 3.
6
The door panel will reproduce a sound to advise that the system has entered into programming
mode.
In systems with more than one door panel, the programming process shall be done on the master
door panel only.
From coded module:
Press the key button three times and then enter the administrator pin he
will
t
module
emit tones
,
:
Make a call to check that the telephone has been successfully programmed. Programme the other
telephones in the same way.
Once the programming has finished, set the
programming switch to OFF
sound module
or press the
key if the programming is from coded module. If this is not done, the door panel will emit tones to
indicate that the system is still in programming mode
.
(programming from sound module)
Each apartment must only have one master unit; if there are parallel units, whether monitors or telephones, they must be
configured as slaves.
With the door release push button pressed, pick up the telephone's handset.
To show that the system is ready for programming, the door panel and handset will emit a
number of tones, and audio communication can be established.
Release the door release push button.
Enter the code to be called by this telephone and press
.
key
At this moment both door panel and handset will emit tones.
Programming T-530 R5
telephones:
SU-R5
PROGRAMMING THE TELEPHONES
92
M
S
AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED DOOR PANEL
Important:
Programming from coded module:
- With EL632 R5 and EL642 R5 sound module V01 or later / EL632 R5 P/T with V03 or later.
- With N3301/AL or NX3301
V03 or later.
access control module
(1)
2
7
1 8
Key key key administrator pin.
Bear in mind the number of digits in the configured code (factory setting 2718 = 4).
(1)
C
0
1
0
1