MODULE DESCRIPTION
8
The wiring terminals are located at the back of the module
and correspond to the following connections:
power supply
.
normally open output relay 1.
common relay 1.
normally closed output relay 1.
normally open output relay 2.
common relay 2.
normally closed output relay 2.
panic output.
negative.
input for external relay 1 button.
input for external relay 2 button.
~, ~ :
NA1 :
C1 :
NC1 :
NA2 :
C2 :
NC2 :
P :
:
PL1 :
PL2
:
_
Description of the N3301/AL - NX3301 module:
Description of the JP1 jumper
:
Tamper alarm mode activated. In this mode, the module's keypad
operation and external buttons are disabled. The LEDs and the keypad's
backlight are turned off and a constant audible alarm and the “P” panic
output of the open collector (3 seconds every minute) are activated.
Alarm mode ends when the JP1 jumper is replaced.
Normal operation, alarm not activated
.
JP1
The JP1 jumper, located on the right-hand side of the connection block,
activates the tamper alarm.
Description of the SW1 DIP switch:
The SW1 DIP switch is located on the left-hand side of the module.
Use to reset the special installer PIN to the factory code.
Proceed as follows: Set DIP switch 1 to ON. The module will emit 2 beeps and
the green LED on the front will light up for 1 second. Then set the DIP switch to
OFF (the code is now the one assigned at the factory). If, during this process, the
access control module was locked, the “special unlock” pin code will also be reset to the
assigned factory code.
No standalone access control function (leave in the OFF position).
*
( )
Factory default setting
.
( )
The access control module features an internal beeper for reproducing operation beeps.
Confirm field
2 rapid beeps
Confirm sequence
4 rapid beeps
Cancel
1 long beep (0.5 sec)
Programming
Operation
5 rapid beeps
Error
1 long beep (1 sec)
Key press
1 rapid beep
Dura
n
tio
Alarm activated
1 constant beep
Description of the beeps: