DESCRIPTION OF THE SOUND MODULES
66
AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED DOOR PANEL
Description of the CN8 Nexa Bus link connector:
The CN8 Nexa Bus link connector is located on the upper left side of the back of the sound
module.
Connect the cable supplied with the module to other modules using the NEXA Bus:
ð
N3403/AL:
Connect the module to provide the system with a display viewer.
ð
N3301/AL:
Connect the module to provide the system with access control and a coded door panel.
ð
EL3002:
Connect to the bus to power information panels (maximum unit).
1
Not :
( FA-V2Plus
,
p
),
e With
power supply see age 64 3 more Nexa modules can be connected.
external power supply"
AUX
ON
DIP
4
3
2
1
5
Master
ON
DIP
4
3
2
1
5
Slave
ON
DIP
4
3
2
1
5
Slave 0
ON
DIP
4
3
2
1
5
Slave 1
ON
DIP
4
3
2
1
5
Door lock release
free
ON
DIP
4
3
2
1
5
Door lock release
privacy
ON
DIP
4
3
2
1
5
On
ON
DIP
4
3
2
1
5
Off
ON
DIP
4
3
2
1
5
Camera lights
Off
Door panel type
Slave door panel
address
Door lock release
Camera lights
ON
DIP
4
3
2
1
5
Camera lights
On
Interruption
SW2 DIP-SWITCH:
*
( )
*
( )
*
( )
*
( )
*
( )
Camera lights: The camera lights may be turned o
ff
if illumination in the surrounding environment is su
ffi
cient at night.
The
configuration rotary switch is located on the upper right side of the back of the sound
SW3
module.
Description of the SW3 rotary switch:
(Guaranteed conversation time).
2
9 0
5
1
SW2
SW4
SW3
3
4
6
7
8
2
9
0
5
1
3
4
6
7
8
*
( )
The posistion of the
rotary switch, determines a guaranteed conversation time, i.e.
SW3
extends the busy time from the answer onwards. (Note: Call time is max. 60 seconds).
Pos. 0 = 1 s Pos. 1 = 10 s Pos. 2 = 20 s Pos. 3 = 30 s ( )
Pos. 4 = 40 s Pos. 5 = 50 s Pos. 6 = 60 s Pos. 7
8 = 70 s
y
Pos. 9 = NOT ALLOWED.
Not :
e
The guaranteed conversation time has to be con
fi
gured the same in all the door panels present in the system.
*
*
( )
Factory default.
The
configuration rotary switch is located on the upper right side of the back of the sound
SW4
module.
Description of the SW4 rotary switch:
(Door lock release time).
2
9 0
5
1
SW2
SW4
SW3
3
4
6
7
8
2
9
0
5
1
3
4
6
7
8
*
( )
The position of the
rotatory switch, determines the activaton time of the main door lock
SW4
(SE+, SE- terminals).
Pos. 0 = 1 s ( )
Pos. 1 = 10 s Pos. 2 = 20 s Pos. 3 = 30 s
Pos. 4 = 40 s Pos. 5 = 50 s Pos. 6 = 60 s Pos. 7 = 70 s
Pos. 8 = 80 s Pos. 9 = 90 s
*
*
( )
factory default.
CN8
Continued from previous page
*
( )
Factory default.
Summary of Contents for NEXA Series
Page 4: ......
Page 5: ...Standalone access control...
Page 23: ...Access control combined with Nexa door panels...
Page 54: ...Coded door panel...
Page 98: ...Coded panel with display...