116
DOOR PANEL OPERATION
Description of door panel operation:
Door panel in standby mode.
With the door panel in standby mode, the following operations can be performed:
A
ctivation of external push buttons:
Allows activation of relay outputs 1, 2 and 3 by means of external push buttons
PL1, PL2 and AP respectively.
The PL1 and PL2 buttons can be configured by means of programming to activate and deactivate the output by
pressing the button or to activate the output by pressing the button and deactivate after a period of between 1 and 99
seconds.
With the keypad:
Special default codes:
(bear in mind the number of digits in the code).
Administrator pin:
271800. 2718 if the number of digits configured = 4.
CP1 button code:
111100. 1111 if the number of digits configured = 4.
CP2 button code:
222200. 2222 if the number of digits configured = 4.
Unlocking code:
333300. 3333 if the number of digits configured = 4.
User pin:
444400. 4444 if the number of digits configured = 4.
Opening through the user pin:
Allows activation of the outputs (relay 1/relay 2/relay 3/panic) associated with the
existing user in the residents list. Press the key button, followed by the user pin.
“key button” + “user pin”.
Administration pin
: Enables entry into the door panel's programming mode and programming of monitors and/or
telephones. Also enables the door panel to be unlocked if previously locked. Press the key button three times and
then enter the administrator or user pin.
“key button” + “key button” + “key button” + “admin pin”.
“key button” + “key button” + “key button” + “user pin”.
CP1 button code:
Enables or disables external button PL1 and/or PL2 associated with the CP1 code. Press the key
button three times and then enter the CP1 code.
“
key button” + “key button” + “key button” + “CP1 code”.
CP2 button code:
Enables or disables external button PL1 and/or PL2 associated with the CP2 code. Press the key
button three times and then enter the CP2 code.
“key button” + “key button” + “key button” + “CP2 code”.
Unlocking code:
Allows the module to be unlocked only if it has previously been locked. Press the key button three
times and then enter the unlocking code.
“key button” + “key button” + “key button” + “unlocking code”.
Change user pin:
Allows users to change their own codes. Does not modify the outputs (relay 1/relay 2/relay 3/panic)
associated with the user. Press the key button twice, followed by the current user pin, then press the key button
again, followed by the new user pin, and then press the key button a final time. The new user pin must have the same
number of digits as the current user pin and cannot be the same as an existing user pin.
“key button” + “key button” + “current user pin” + “key button” + “new user pin” + “key button”.
Call to monitors and telephones
: This enables calls to be made to monitors and/or telephones connected to the
same installation. Press the monitor or telephone code followed by the bell button.
“monitor/telephone code” + “bell”.
Calls to monitors and telephones through the residents list
: This enables calls to be made to monitors and/or
telephones connected to the same installation. Search for the resident using the arrow keys and press bell to make the
call.
“Search resident using arrows button” + “bell”.
AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANEL WITH DISPLAY
Summary of Contents for NEXA Series
Page 4: ......
Page 5: ...Standalone access control...
Page 23: ...Access control combined with Nexa door panels...
Page 54: ...Coded door panel...