21
MODULE PROGRAMMING
Factory setting:
-
Special codes:
Bear in mind the number of digits in the code (see p. 10).
Administrator pin: 271800. 2718 if the number of digits configured = 4.
CP1 button code: 111100.
1111 if the number of digits configured = 4.
CP2 button code: 222200.
2222 if the number of digits configured = 4.
Unlocking code: 333300.
3333 if the number of digits configured = 4.
-
Number of digits in user and special codes:
Programming field
“
0
”
(page 12)
Step 2:
“
4
” –
4 digit code.
-
Setting relay 1:
Programming field
“
4
”
(page 16).
Step 3:
“
0
”
Impulse.
Step 4:
“
03
”
Activation time (seconds).
-
Setting relay 2:
Programming field
“
4
”
(page 16).
Step 3:
“
0
”
Impulse.
Step 4:
“
03
”
Activation time (seconds).
-
Setting the panic output:
Programming field
“
4
”
(p. 16).
Step 3:
“
0
”
Impulse.
Step 4:
“
10
”
Activation time (seconds).
-
Setting external push button PL1:
Programming field
“
5
”
(page 17).
Step 3:
“
1
”
Enable/disable the functioning of the push button with button code CP1.
Step 4:
“
10
”
Activation time (seconds).
-
Setting external push button PL2:
Programming field
“
5
”
(page 17).
Step 3:
“
2
”
Enable/disable the functioning of the push button with button code CP2.
Step 4:
“
05
”
Activation time (seconds).
-
Setting locking mode:
Programming field
“
6
”
(page 18).
Step 2:
“
3
”
Maximum number of failed attempts to enter user pin.
Step 3:
“
03
”
Minimum time between failed attempts (minutes).
Step 4:
“
03
”
Duration of locking mode (minutes).
Step 5:
“
1
”
The panic output is activated during locking mode.
-
Setting identification ID:
Programming field
“
7
”
(page 19) (
).
Not to be configured
Step 2:
“
000
”
Identification ID. Do not modify this field value.
-
Setting depth of field:
Programming field
“
8
”
(page 19) (
).
Not to be configured
Step 2:
“
3
”
Depth of field. Do not modify this field value.
Step 3:
“
0
”
Direct call disabled. Do not modify this field value.
-
Setting the keypad beep:
Programming field
“
9
”
(see page 20).
Step 2:
“
1
”
Beep when keypad buttons pressed (activated).