C 2 MODE
P
C 2 TIME
P
C 1 TIME
P
C 2 CODE
P
PROGRAMMING THE DOOR PANEL
Determines the time in seconds that the output associated with the P2
button (relay R2) will remain activated.
To change the time, press
and the message ENTER VALUE will appear;
enter the time to be assigned to the output and con
fi
rm by pressing
.
Press the
button to restore the previous value.
ENTER VALUE
:03
1 0
C 2 MODE
P
C 2 TIME
P
C 1 TIME
P
C 2 CODE
P
C 2 MODE
P
10s
C 1 TIME
P
C 2 CODE
P
C 2 TIME
P
UNLOCKING CODE
C 2 CODE
P
C 2 MODE
P
ENTER VALUE
:3333
6 7
4 5
C 2 TIME
P
UNLOCKING CODE
C 2 CODE
P
C 2 MODE
P
C 2 TIME
P
4567
C 2 CODE
P
C 2 MODE
P
Enables the code for unlocking the door panel to be changed when the
wrong access codes are entered and the door panel is locked (de
fi
ned by
the LOCK MODE
fi
eld).
To change, press
and the message ENTER VALUE will appear; enter the
unlock code using the numeric keypad and con
fi
rm by pressing
. Press
to
restore the previous value.
The code must have the same number of digits as the previous one, between
4 and 6, depending on the NUMBER OF DIGITS value con
fi
gurable from
the SYSTEM SETTINGS menu. The factory setting is 4.
UNLOCKING CODE
LOCKING MODE
C 2 MODE
P
C 2 TIME
P
Determines the number of attempts that can be made before access control is
locked. Settings range from NEVER LOCK to between 3 and 9 ATTEMPTS.
To change, press
until the required setting is reached.
LOCKING MODE
LOCKING TIME
C 2 TIME
P
UNLOCKING CODE
ENTER VALUE
:03
0 6
Determines the time in minutes that the door panel will remain locked before
the access code is restored in the event of a higher number of attempts than
that con
fi
gured in LOCK MODE. Between 3 and 15 minutes can be de
fi
ned.
To change the time, press
and the message ENTER VALUE will appear;
enter the time to be assigned and con
fi
rm by pressing
.
Press the
button to restore the previous value.
128
Access control menu
Continued from previous page
AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANEL WITH DISPLAY
Continued overleaf