51
WIRING DIAGRAMS
Combined with Nexa Modular / Nexa Stainless Steel panels:
Door panels with EL63 PLUS
-
2
P/T
EL64 PLUS sound module
2
N3301
access control module
FA-Plus or FA-Plus/C
power supply unit
C2
NC1
NC2
CN1
P
~ ~
SEC
+ -
PRI
~
~
Main
CN1
+
-
-
+
CV1
CV2
Electronic or video access control systems with digital installation.
The wiring of the access control module with 'Nexa Modular/Nexa Stainless Steel'
panels will vary depending on the type
of installation. Use the same power supply unit as the panels.
10
1
9
2
8
3
7
4
6
5
CN3
C1
NA1
NA2
PL1 PL2
-
Door panels with EL63 R5
-
2
P/T
EL64 R5 sound module
2
N3301
access control module
FA-Plus/C
power supply unit
C2
NC1
NC2
CN1
P
~ ~
SEC
+ -
PRI
~
~
Main
CN1
+
-
+
CV1
CV2
C1
NA1
NA2
PL1 PL2
-
-
+12
-
AUDIO AND VIDEO DOOR ENTRY SYSTEM - ACCESS CONTROL
N
OTE: To connect the modules to an
module, use the
EL632
EL642
Plus P/T ,
R5 P/T or
Plus or EL632
EL642 R5
NEXA Bus hose. See p. 7 to check the wiring and p. 9 to check the wiring diagram.
1
3
Summary of Contents for NEXA Series
Page 4: ......
Page 5: ...Standalone access control...
Page 23: ...Access control combined with Nexa door panels...
Page 54: ...Coded door panel...
Page 98: ...Coded panel with display...