MODULE OPERATION
10
Module in standby mode.
With the module in standby mode, the following operations can be performed:
Activation of external push buttons:
Allows activation of relay outputs 1 and 2 by means of external push buttons
PL1 and PL2 respectively
.
The push button can be configured by means of programming to activate and deactivate the output by pressing the
button or activate the output by pressing the button and deactivate after a period of between 1 and 99 seconds
.
With the keypad
:
Special default codes: (bear in mind the number of digits in the code).
Administrator pin:
271800. 2718 if the number of digits configured = 4.
CP1 button code:
111100. 1111 if the number of digits configured = 4.
CP2 button code:
222200. 2222 if the number of digits configured = 4.
Unlocking code:
333300. 3333 if the number of digits configured = 4.
Opening through the user pin:
Allows activation of the outputs (relay 1/relay 2/panic) associated with the existing
user. Press the key button, followed by the user pin.
“key button” + “user pin”.
Administrator pin:
Allows entry into programming mode. Also enables the panel to be unlocked if it has been
previously locked. Press the key button three times and then enter the administrator pin.
“key button” + “key button” + “key button” + “administrator pin”.
CP1 button code:
Enables or disables external button PL1 and/or PL2 associated with the CP1 code. Press the key
button three times and then enter the CP1 code.
“key button” + “key button” + “key button” + “CP1 code”.
CP2 button code:
Enables or disables external button PL1 and/or PL2 associated with the CP2 code. Press the key
button three times and then enter the CP2 code.
“key button” + “key button” + “key button” + “CP2 code”.
Unlocking code:
Allows the module to be unlocked only if it has previously been locked. Press the key button three
times and then enter the Unlocking code.
“key button” + “key button” + “key button” + “unlocking code”.
Change user pin:
Allows users to change their own codes. Does not modify the outputs (relay 1/relay 2/panic)
associated with the user. Press the key button twice, followed by the current user pin, then press the key button
again, followed by the new user pin, and then press the key button a final time. The new user pin must have the same
number of digits as the current user pin and cannot be the same as an existing user pin.
“key button” + “key button” + “current user pin” + “key button” + “new user pin” + “key button”.