95
About GSK tightening setting additional items
①
Judgment area
You set the area value to be used for judging screw defects.
Calculation of area value is obtained by integral calculation on torque and angle curve
during Pre-tightening cycle (option setting item in case of Real tightening).
With the tightening waveform of the automatic measurement item in the setting software,
you can check the waveform used for this calculation.
To see this waveform, you select "Extended waveform".
②
Smooth tightening
This tightening controls the rotational speed steplessly.
You can set this tightening method by the option of the final tightening cycle.
By setting initial speed and the speed at the cutting torque,
the rotation speed changes steplessly according to the change of torque.
Summary of Contents for GSK Series
Page 1: ...Instruction Manual GSK GSKW Controller November 2017 GIKEN INDUSTRIAL CO LTD The 3rd edition...
Page 16: ...15 Size Interface dimensions Standard type GSK IF...
Page 17: ...16 Controller dimensions Standard type GSK 4 GSKW 4...
Page 18: ...17 Controller dimensions Standard type GSK 5 7...
Page 19: ...18 Controller dimensions T type GSK T5 T7...
Page 20: ...19 Controller dimensions Standard type GSKW 5...
Page 21: ...20 Controller dimensions T type GSKW T5...
Page 22: ...21 Dimensions display Model GSK D1 Panel cut out dimensions Back Side Front Under...
Page 24: ...23 M net ver GSK Controller system wiring reference diagram...
Page 28: ...27 External connection diagram I F unit Connected equipment standard and T type...
Page 50: ...49 Setting...
Page 58: ...57 Reverse tightening reference waveform...
Page 62: ...61...
Page 63: ...62 Gradient calculation method...