31
4-2
Input and output signals
4-2-1
Input and output signals
Input
(
“PLC”→“GSK”
)
No.
Bit
Name
Matter
0
0
Operation ready
This is the opration ready comand
0
:
Stop(
Operation prohibition.The GSK Interface doesn’t run.)
・
Start signal cannot be accepted.
・
It stops the motor at emergency stop if it becomes 0 operation.
1
:
This operation enabled state.
・
The output signal[Operation ready] becomes 1 operation when
the GSK can oprate.
0
1
Automatic/Manual
Choose Automatic or manual operation
0: The manual actions can be oprated
Input siganl
Action
Inching start
Nut runner does inching action
JOG start
The nut runner move to the
specified position
XJOG/YJOG
JOG motion Xaxis/Yaxis
【
on Positoning mode
】
Othe than the above, automatic operation is possible.
1: The automatic operation is possible to start
Input siganl
Action
start
【
On multi-axis mode
】
It actions only 1 block.
When it exit,it waits for the next
start.
【
on Positoning mode
】
Some set blocks are performed
continuously
0
2
Start
GSK will start the program execution at the rising edge of the
start bit (start bit: 0
⇒
1).
You also need to maintain the 1 at start bit during operation.
If 1 become 0 to suspend, the automatic operation becomes a
cycle stop state during the operation.
0
3
Inching start
GSK will start the inching action at the rising edge of the inching
start bit (inching start bit: 0
⇒
1).
0
4
Determination
reset
GSK will reset the
determination
result at the rising edge of the
determination
reset bit (
determination
reset bit: 0
⇒
1).
Only when it receives the output signal of the program operation
end (Total OK bit or Total NG bit : 0
⇒
1)GSK will accept this reset
signal
0
5
Alerm reset
GSK will reset the alarm condition at the rising edge of the Alerm
reset bit (Alerm reset bit: 0
⇒
1).
If successful Alarm reset (if driving preparation signal is ON)
operation ready signal will return to ON.
0
6
QL sginal
QL signal is input at the rising edge of the i QL signal bit (QL
signal bit: 0
⇒
1).
0
7
QL mode
GSK Indicates whether to accept the QL signal
。
0
:
unavailable
1
:
Effectiveness
This_signal_bit must become 1 when it does QL operation.
Summary of Contents for GSK Series
Page 1: ...Instruction Manual GSK GSKW Controller November 2017 GIKEN INDUSTRIAL CO LTD The 3rd edition...
Page 16: ...15 Size Interface dimensions Standard type GSK IF...
Page 17: ...16 Controller dimensions Standard type GSK 4 GSKW 4...
Page 18: ...17 Controller dimensions Standard type GSK 5 7...
Page 19: ...18 Controller dimensions T type GSK T5 T7...
Page 20: ...19 Controller dimensions Standard type GSKW 5...
Page 21: ...20 Controller dimensions T type GSKW T5...
Page 22: ...21 Dimensions display Model GSK D1 Panel cut out dimensions Back Side Front Under...
Page 24: ...23 M net ver GSK Controller system wiring reference diagram...
Page 28: ...27 External connection diagram I F unit Connected equipment standard and T type...
Page 50: ...49 Setting...
Page 58: ...57 Reverse tightening reference waveform...
Page 62: ...61...
Page 63: ...62 Gradient calculation method...