72
Number
Matter
Setting
range
Increments
No.07
Communication speed of the external display (bps)
0:38400
1:57600
2:76800 3:115200
【
Note: the operation of the later version 1721-141
】
When the power is ON it will connect at the optimal speed to check the
communication speed of the display.
This setting is the default communication speed in the case of the
connection between the power is turned ON display it could not be
confirmed.
Please combine this setting with the communication speed of display as
possible.
0-3
―
No.08
Print Settings (hexadecimal data)
This sets the conditions relating to the printer output.
BIT7: new line code specified (0: LF 1: CR + LF)
BIT6-3: unused
BIT1-0: Auto Print selection (00: N / 01: every time 10: NG at the time /
11: First N stand + when NG)
―
―
No.09
Online print mode
BIT5: print format (0: Standard 1: Jamco specification)
BIT4: zero times result print presence or absence
BIT3: Print the presence or absence of this tightening results
BIT2: Print the presence or absence of the reverse result
BIT1: temporary tightening result print presence or absence
BIT0: socket alignment prints presence or absence
―
―
No.10
Initial number
(N at the time of the "automatic printing selected first N stand" of No08
Print Settings)
―
―
No.11
QL setting
※
This feature is enabled by Version1721-170 below.
―
―
No.12
PLC setting
This sets the such as IO size of the PLC to be connected to the Anybus
board. Please set the parameters according to the PLC to be connected.
Meaning of the value depends on the Anybus board.
―
―
No.13
~
No.19
Reserve
―
―
Summary of Contents for GSK Series
Page 1: ...Instruction Manual GSK GSKW Controller November 2017 GIKEN INDUSTRIAL CO LTD The 3rd edition...
Page 16: ...15 Size Interface dimensions Standard type GSK IF...
Page 17: ...16 Controller dimensions Standard type GSK 4 GSKW 4...
Page 18: ...17 Controller dimensions Standard type GSK 5 7...
Page 19: ...18 Controller dimensions T type GSK T5 T7...
Page 20: ...19 Controller dimensions Standard type GSKW 5...
Page 21: ...20 Controller dimensions T type GSKW T5...
Page 22: ...21 Dimensions display Model GSK D1 Panel cut out dimensions Back Side Front Under...
Page 24: ...23 M net ver GSK Controller system wiring reference diagram...
Page 28: ...27 External connection diagram I F unit Connected equipment standard and T type...
Page 50: ...49 Setting...
Page 58: ...57 Reverse tightening reference waveform...
Page 62: ...61...
Page 63: ...62 Gradient calculation method...