67
7-10
Point setting
It will remember the XY coordinates of each unit in the form of a point number.
If GSKIF instructs the move to GSK driver, specify the point number, not the coordinate value.
Number is the number of the case to be set from GSK driver panel (= x-yyy-z).
The x is the unit number (1 ~ 4), yyy is point number (1 ~ 255), z indicates the axis type.
Number
(yy)
Matter
Setting
range
Increments
No.000
~
No.254
Point coordinate value (Point number1
~
255)
Set the coordinate values of the point of the X-axis.
※
Axis type (z):0 is the X-axis, 1 is the Y-axis.
0000-9999
0.1mm
No.255 Reserve
―
―
No256
Set the adjacent interference distance 1 to 8.
The combination of the unit number (x) and the shaft type (z) shows the
following value.
Unit number(x)
Axis type(z)
Meaning
1
0
1
Adjacent interference distance 1
Adjacent interference distance 2
2
0
1
Adjacent interference distance 3
Adjacent interference distance 4
3
0
1
Adjacent interference distance 5
Adjacent interference distance 6
4
0
1
Adjacent interference distance 7
Adjacent interference distance 8
―
―
No257
Set the soft limit (+ direction).
Set the upper operating limit coordinate value according to the unit
number (x) and the shaft type (z).
―
―
No258
Set the adjacent interference distance 9 to16.
The combination of the unit number (x) and the shaft type (z) shows the
following value.
Unit number(x)
Axis type(z)
Meaning
1
0
1
Adjacent interference distance 9
Adjacent interference distance 10
2
0
1
Adjacent interference distance 11
Adjacent interference distance 12
3
0
1
Adjacent interference distance 13
Adjacent interference distance 14
4
0
1
Adjacent interference distance 15
Adjacent interference distance 16
―
―
No.259
~
No.266
Each individual operation interlock setting
(GSK is not used because it has no function.)
―
―
No267
Adjacent interference check invalid setting
BIT1
0:check
1:not check
※
Note that the check "to" 0
―
―
No268
Set the soft limit (- direction).
Set the lower operating limit coordinate value according to the unit
number (x) and the shaft type (z).
―
―
No269
~
No.287
Reserve
―
―
Summary of Contents for GSK Series
Page 1: ...Instruction Manual GSK GSKW Controller November 2017 GIKEN INDUSTRIAL CO LTD The 3rd edition...
Page 16: ...15 Size Interface dimensions Standard type GSK IF...
Page 17: ...16 Controller dimensions Standard type GSK 4 GSKW 4...
Page 18: ...17 Controller dimensions Standard type GSK 5 7...
Page 19: ...18 Controller dimensions T type GSK T5 T7...
Page 20: ...19 Controller dimensions Standard type GSKW 5...
Page 21: ...20 Controller dimensions T type GSKW T5...
Page 22: ...21 Dimensions display Model GSK D1 Panel cut out dimensions Back Side Front Under...
Page 24: ...23 M net ver GSK Controller system wiring reference diagram...
Page 28: ...27 External connection diagram I F unit Connected equipment standard and T type...
Page 50: ...49 Setting...
Page 58: ...57 Reverse tightening reference waveform...
Page 62: ...61...
Page 63: ...62 Gradient calculation method...