99
・
HISTORY.CSV file
When the SD card is inserted into the slot of the GSK-IF, the tightening result is written to the SD card.
"HISTORY.CSV" is the file which the tightening result is written at this time.
The file name actually saved is "0000_his.CSV".
Below is a description of the number in the above figure.
①
: This is the title of the history. "Result" is fixed.
The data etc. read by the support system are not shown in this notation, please use it to distinguish.
②
: The details of the tightening result are shown.
The result data is saved in the same format as "Online" of the setting software.
③
: Sampling data which used for waveform image creation is recorded.
It records torque, angle, rotation speed every 10 msec.
About 1000 items can be saved in this file (
※
).
If it is over, it names the current history file by date and time and it saves the result to a new history file.
Please refer to the table below for name change.
Order
Contents
String
1
st
and 2
nd
Character
Renamed date
01
~
31
3
rd
and 4
th
Character
Renamed hours
00
~
23
5
th
and 6
th
Character
Renamed minutes
00
~
59
7
th
Character
Renamed second (10 of digits)
0
~
5
8
th
Character
Renamed month
1
~
9,A(October),B(1November),C(December
)
(Example: When splitting at 23:50:35 on October 3
⇒
"0323503 A. CVS")
If a file with the same name already exists, it delete the existing file and it rename the current file.
①
②
③
Summary of Contents for GSK Series
Page 1: ...Instruction Manual GSK GSKW Controller November 2017 GIKEN INDUSTRIAL CO LTD The 3rd edition...
Page 16: ...15 Size Interface dimensions Standard type GSK IF...
Page 17: ...16 Controller dimensions Standard type GSK 4 GSKW 4...
Page 18: ...17 Controller dimensions Standard type GSK 5 7...
Page 19: ...18 Controller dimensions T type GSK T5 T7...
Page 20: ...19 Controller dimensions Standard type GSKW 5...
Page 21: ...20 Controller dimensions T type GSKW T5...
Page 22: ...21 Dimensions display Model GSK D1 Panel cut out dimensions Back Side Front Under...
Page 24: ...23 M net ver GSK Controller system wiring reference diagram...
Page 28: ...27 External connection diagram I F unit Connected equipment standard and T type...
Page 50: ...49 Setting...
Page 58: ...57 Reverse tightening reference waveform...
Page 62: ...61...
Page 63: ...62 Gradient calculation method...