94
Supplemental explanation
Precautions for wiring the arc net.
Please use the following drawing for the arc net wiring.
Set 110Ω resister to (+)(-) on the arc net connector of the end unit driver .
Precautions to use M-net communication
Make sure to set the SIO start address setting “Fn12 No.13” from the controller panel when SIO is selected for
the communication with PLC. (If the PLC address does not match the GSK controller SIO start address, the
communication between PLC and GSS cannot be established.
Password to write the setting data to GSK PC
Password when the setting is written: 2014
Driver unit
Driver unit
Driver unit
Driver unit
I/F unit
110Ω
resistance