14
2-3
Functions/Features
Protective function
Over current, over load, over speed, encoder failure, drive power
failure, E2PROM failure and CPU failure, etc.
Display
function
7SEGMENT
LED
Alarm No., NG information
Program No., Block No.
Operation monitor
Tightening result (Torque, etc.)
Parameter setting
Set the following parameters by a personal computer and input
them to the IF unit.
.
Program 16 or 50
.
Rating 30
.
PRE.T
.
REA.T Each 50
.
REV.T
.
SOC.T
Storing the tightening data
Tightening data:
About 5,000 per axis
Alarm history:16 per axis
Tightening waveform:1 per axis
It is possible to check the data when needed from PC
Applicable to the multiaxial
1 to 30 units of controller or 1 to 15 units of double type controller
can be connected to 1 Interface unit.
Max. 30 axes multiaxial control is possible
Communication with the
PLC (in serial or parallel)
Communication by multi-standard using the Anybus
※
Please refer to 2-2 in regard corresponding standard
Axis cutting function
Setting for axis cutting is possible by the PC setting or the
operation from the front panel.
(Used when the controller malfunctioned)
Zero magnification check
function
Diagnosis function for the torque sensor malfunction (Performs
per tightening operation)
Gear check function
Diagnosis function for biting of the gear and motor shaft
(Selectable for Yes/No)
Simulation movement
Simulation movement is available by the personal computer
operation
(Sampling start for the seating angle by tightening)
Calendar function
It saves the Year, Month, Day, Hour, Minute and Second per data.
Regenerative function (Over
voltage detection)
Regeneration circuit that visceral the driving voltage is consumed
by the internal resistor when it exceeds a predetermined value.
Discharge function
Natural discharge by the LED
Standard inertia (INERTIA)
JL
≦
30JM
Rotating direction
Direction of CCW should be the forward rotation viewed from
motor shaft end.
Analog monitor
(
P81
reference
)
Monitor signal output at the check pin on the front panel:
M1 ... The torque, an electric current and speed can be
M2 ... monitored every each controller in panel operation.
G ... Monitor GND
Summary of Contents for GSK Series
Page 1: ...Instruction Manual GSK GSKW Controller November 2017 GIKEN INDUSTRIAL CO LTD The 3rd edition...
Page 16: ...15 Size Interface dimensions Standard type GSK IF...
Page 17: ...16 Controller dimensions Standard type GSK 4 GSKW 4...
Page 18: ...17 Controller dimensions Standard type GSK 5 7...
Page 19: ...18 Controller dimensions T type GSK T5 T7...
Page 20: ...19 Controller dimensions Standard type GSKW 5...
Page 21: ...20 Controller dimensions T type GSKW T5...
Page 22: ...21 Dimensions display Model GSK D1 Panel cut out dimensions Back Side Front Under...
Page 24: ...23 M net ver GSK Controller system wiring reference diagram...
Page 28: ...27 External connection diagram I F unit Connected equipment standard and T type...
Page 50: ...49 Setting...
Page 58: ...57 Reverse tightening reference waveform...
Page 62: ...61...
Page 63: ...62 Gradient calculation method...