Setting function details
7-1
Fn. ** Display setting function list
It can set internal data and modify and monitor at the panel surface of the GSK controller.
Select data
Matter of display data
Remarks
Fn0-00
status of 2-axis motion
Special display
Fn 0-01
I / O status
Display in the code the state of the DI
and DO
Fn 0-02
Product Model
"021.0xx" xx is No. N upper two digits
Fn 0-03
Firm-ware program number
―
Fn 0-04
Firm-ware version number
―
Fn 0-05
At the time, minutes, and seconds
It displays the current time
Fn 0-06
date
It displays the date
Fn 1-00
~
42
The first axis of the screw tightening
result monitor
―
Fn 2-00
~
42
The second axis of the screw
tightening result monitor
―
Fn 3-00
~
19
M-Net input / output monitor
―
Fn 4-00
~
01
Printer output settings
(Note 1)
Fn 5-01
~
30
Setting the unit number
(Note 1)
Fn 6-00
~
19
Setting of the I / F parameter
(Note 1)
Fn 7-00
~
03
Setting the ID controller
(Note 1)
Axx-yy
Parameter of the "SOC.T" operation xx < 50 , yy < 16:
(Note 1)
Lxx-yy
Parameter of the "PRET" operation
xx < 50 , yy < 32:
(Note 1)
Gxx-yy
Parameter of the "REV.T" operation
xx < 50 , yy < 16:
(Note 1)
Hxx-yy
Parameter of the "REA.T" operation xx < 50 , yy < 48:
(Note 1)
Uxx-yy
Parameter of the "RATE" operation
xx < 30 , yy < 10:
(Note 1)
Xxx-yy
Parameter of the "X-axis RATE"
operation
xx
<
30
,
yy
<
16:
(Note 1)
Yxx-yy
Parameter of the "Y-axis RATE"
operation
xx
<
30
,
yy
<
16:
(
Note 1)
Pu.xxx.y
XY position movement point
coordinates
u:1
~
4
,
xxx
<
288
,
y
<
2
(Note 2)
d0xxxx
Any data monitor of the 1th-axis
3 < xxxx
≦
200: Can be changed
(Note 3)
d1xxxx
Any data monitor of the 2th-axis
3 < xxxx
≦
200: Can be changed
(Note 3)
r0xxxx
The 1th axis of history data monitor
Address of FRAM , Data of 0xxxxh
r1xxxx
The 2th axis of history data monitor
Address of FRAM , Data of 1xxxxh
※
Note 1: When the data selection mode, the data sent to the controller in the long press
"←".
※
Note 2: u is the unit number, xxx is point number, X coordinate in the y = 0, Y coordinate in the y = 1.
xxx> = 255 data limit coordinate data
※
Note 3:At time of data selection mode, it
save the data of xxxx <200 in the long press of the "←"
Summary of Contents for GSK Series
Page 1: ...Instruction Manual GSK GSKW Controller November 2017 GIKEN INDUSTRIAL CO LTD The 3rd edition...
Page 16: ...15 Size Interface dimensions Standard type GSK IF...
Page 17: ...16 Controller dimensions Standard type GSK 4 GSKW 4...
Page 18: ...17 Controller dimensions Standard type GSK 5 7...
Page 19: ...18 Controller dimensions T type GSK T5 T7...
Page 20: ...19 Controller dimensions Standard type GSKW 5...
Page 21: ...20 Controller dimensions T type GSKW T5...
Page 22: ...21 Dimensions display Model GSK D1 Panel cut out dimensions Back Side Front Under...
Page 24: ...23 M net ver GSK Controller system wiring reference diagram...
Page 28: ...27 External connection diagram I F unit Connected equipment standard and T type...
Page 50: ...49 Setting...
Page 58: ...57 Reverse tightening reference waveform...
Page 62: ...61...
Page 63: ...62 Gradient calculation method...