24
3-2.
Used connector and mating connector
3-2-1
GSK Used connector and mating connector
GSK driver unit (14/T4)
Port No.
Use
/
Matter
Used model
Matching model
Matching model pin annexed
CN1
For the control power
supply connection
734-166
(
WAGO
)
734-106
(
WAGO
)
―
○
CN2
Not used
1-1827864-4
(
TYCO
)
1-1827864-4
(
TYCO
)
1827570-2
(
TYCO
)
―
CN3
For communication
among controllers at
ARCNET
MSTB2,5/6-STF-5,08
(
PHOENIX
CONTACT
)
MSTB2,5/6-STF-5,08
(
PHOENIX
CONTACT
)
―
○
CN10
For the driving power
supply connection
1-179277-2
(TYCO)
1-178128-4
(TYCO)
1-175218-2
(
TYCO
)
○
CN11
For power line
of nutrunner 1
2-179277-2
(TYCO)
2-178128-4
(TYCO)
1-353717-2
(
TYCO
)
○
CN12
For power line
of nutrunner 2
2-179277-2
(TYCO)
2-178128-4
(TYCO)
1-353717-2
(
TYCO
)
○
CN21
For sensor line
of nutrunner1
10220-52A2PL
(
3MJapan
)
10320
-52A0-008
(
3MJapan
)
10120-3000VE
(
3MJapan
)
○
CN22
For sensor line
of nutrunner2
10220-52A2PL
(
3MJapan
)
10320
-52A0-008
(
3MJapan
)
10120-3000VE
(
3MJapan
)
○
GSK driver unit (15/T5, 17/T7)
Port No.
Use
/
Matter
Used model
Matching model
Matching model pin annexed
CN10
For the driving power
supply connection
1-917541-2
(TYCO)
1-179958-4
(TYCO)
316040-2
(TYCO)
○
CN11
For power line
of nutrunner 1
2-917541-2
(TYCO)
2-179958-4
(TYCO)
316040-2
(TYCO)
○
CN12
For power line
of nutrunner 2
2-917541-2
(TYCO)
2-179958-4
(TYCO)
316040-2
(TYCO)
○
Summary of Contents for GSK Series
Page 1: ...Instruction Manual GSK GSKW Controller November 2017 GIKEN INDUSTRIAL CO LTD The 3rd edition...
Page 16: ...15 Size Interface dimensions Standard type GSK IF...
Page 17: ...16 Controller dimensions Standard type GSK 4 GSKW 4...
Page 18: ...17 Controller dimensions Standard type GSK 5 7...
Page 19: ...18 Controller dimensions T type GSK T5 T7...
Page 20: ...19 Controller dimensions Standard type GSKW 5...
Page 21: ...20 Controller dimensions T type GSKW T5...
Page 22: ...21 Dimensions display Model GSK D1 Panel cut out dimensions Back Side Front Under...
Page 24: ...23 M net ver GSK Controller system wiring reference diagram...
Page 28: ...27 External connection diagram I F unit Connected equipment standard and T type...
Page 50: ...49 Setting...
Page 58: ...57 Reverse tightening reference waveform...
Page 62: ...61...
Page 63: ...62 Gradient calculation method...