
71
7-16
(Fn.6)
Interface unit setting
Number
Matter
Setting
range
Increments
No.00
To select equipment type:
Here you select the type of equipment.
This setting is used in the adjacent interference check
in the positioning mode.
0000:Standard coordinate
0001: Special coordinate1
0002: Special coordinate2
0000/0002
―
No.01
The maximum waiting time of waveform read in quality management PC
【
Multi axis mode
】
This setting is not used in this mode.
【
Positioning mode
】
It sets the maximum time to wait when it reads the waveform to the
quality control personal computer.
The quality control personal computer will read the waveform at the end
of a block, but the reading of the waveform is needs the many time.
This setting is a timer in order to hold between the read.
1
~
9:Waiting time
0:Quality management PC is invald
[Set 1 or more]
It is pending the execution of the next block until it finishes reading
waveform of all the units by the personal computer at the end of a block.
If the waveform reading finshed earlier than the setting time, it will start
the next block as soon as reading is over.
⇒
When the reading of the wave pattern of all units is not finished even if
it reaches in waiting time, I start the next blocking.
※
This setting is the setting for the quality control personal computer, but
the behavior is the same if you have connected the setting personal
computer. Please be sure to set a 0 if you do not want to connect the
quality management PC.
0000-0009
sec
No.02
Screw number for ID output
It sets the maximum number of for a single work.
0000-0099
―
No.03
This sets the communication speed of the personal computer (1 byte data
of hexadecimal)
communication speed of setting personal computer (bps)
*
0:9600
*
1:19200
*
2:38400
communication speed of quality control personal computer (bps)
*
0
:
19200
*
1
:
38400
0000-0012
―
No.04
Setting of the external display
(Decimal data)
1th digit: Display valid (0: Invalid 1: Valid)
2th digit: Language switching (0: Japanese 1: English)
※
Language will be changed by sending the information
of the language switching to an external display.
0000-0011
―
No.05
M-NET signal monitor unit selection
This select the unit number (1 to 7) to be displayed in GSK driver panel
according to the M-NET signal monitor (Fn03).
If set to 0 will be the state monitoring of GSK interface.
0001-0007
―
No.06
Waveform resolution to an external display
The resolution of the waveform data when transmitted to an external
display in 0.5-degree increments.
(For example, 0.5 degrees: 05,1.0 degrees: 10,1.5 degrees: 15,2.0
degrees: 20)
0005-0095
0
.
1degree
Summary of Contents for GSK Series
Page 1: ...Instruction Manual GSK GSKW Controller November 2017 GIKEN INDUSTRIAL CO LTD The 3rd edition...
Page 16: ...15 Size Interface dimensions Standard type GSK IF...
Page 17: ...16 Controller dimensions Standard type GSK 4 GSKW 4...
Page 18: ...17 Controller dimensions Standard type GSK 5 7...
Page 19: ...18 Controller dimensions T type GSK T5 T7...
Page 20: ...19 Controller dimensions Standard type GSKW 5...
Page 21: ...20 Controller dimensions T type GSKW T5...
Page 22: ...21 Dimensions display Model GSK D1 Panel cut out dimensions Back Side Front Under...
Page 24: ...23 M net ver GSK Controller system wiring reference diagram...
Page 28: ...27 External connection diagram I F unit Connected equipment standard and T type...
Page 50: ...49 Setting...
Page 58: ...57 Reverse tightening reference waveform...
Page 62: ...61...
Page 63: ...62 Gradient calculation method...