PROCEDURES
9 Check the ambient air temperature and adjust
the specific gravity reading for each cell as
follows:
•
Add 0.004 to the reading of each cell for
every 10° / 5.5° C above 80° F / 26.7° C.
•
Subtract 0.004 from the reading of each cell for
every 10° / 5.5° C below 80° F / 26.7° C.
Result: All battery cells display a specific
gravity of 1.277 +/- 0.007. The battery is fully
charged. Proceed to step 10.
Result: One or more battery cells display a
specific gravity from 1.269 to 1.218. The battery
is still usable, but at a lower performance so will
need to be recharged more often. Proceed to
step 11.
Result: One or more battery cells display a
specific gravity from 1.217 to 1.173. The battery
is approaching the end of its life. Proceed to
step 11.
Result: The difference in specific gravity
readings between cells is greater than 0.1 OR
the specific gravity of one or more cells is 1.172
or less. Replace the battery.
10 Check the battery acid level. If needed,
replenish with distilled water to
1
/
8
inch / 3 mm
below the bottom of the battery fill tube. Do not
overfill.
11 Install the vent caps and neutralize any
electrolyte that may have spilled.
B-2
Inspect the Electrical Wiring
Note: Genie specifications require that this
procedure be performed every 250 hours or
quarterly, whichever comes first.
Maintaining electrical wiring in good condition is
essential to safe operation and good machine
performance. Failure to find and replace burnt,
chafed, corroded or pinched wires could result in
unsafe operating conditions and may cause
component damage.
Electrocution/burn hazard. Contact
with hot or live circuits could result
in death or serious injury. Remove
all rings, watches and other
jewelry.
1 Remove the drive chassis cover from the
non-steer end of the machine.
2 Inspect the following areas for burnt, chafed,
corroded and loose wires:
• Electrical power panel
• Electrical relay panel
• Ground control panel
• Function manifold wiring
Summary of Contents for Z-30/20N
Page 1: ......
Page 148: ...6 46 June2011 Section 6 Schematics 6 45 Power Cable Wiring Diagram...
Page 149: ...6 47 Section 6 Schematics June2011 6 48 Drive Contactor Panel Wiring Diagram...
Page 152: ...6 50 June2011 Section 6 Schematics Manifold and Limit Switch Wiring Diagram 6 49...
Page 153: ...6 51 Section 6 Schematics June2011 6 52 LVI BCI Option Wiring Diagram...
Page 156: ...6 54 June2011 Section 6 Schematics 6 53 Charger Interlock Option...
Page 157: ...6 55 Section 6 Schematics June2011 6 56 CTE Option CE Models...
Page 160: ...6 58 June2011 Section 6 Schematics Hydraulic Schematic 6 57...