NetworX Version 3 Installation Manual
126
7
=
On: if configuration group is
force armable
8
=
On: if configuration group is
entry guard
Segment 3
1 =
On: enables
Fast Loop
Response. (50mS) - Off= 500mS
2
=
On: enables Double
End Of Line Tamper
zone. (Mainly used for tamper on
wireless zones)
3
=
On: enables
Trouble Reporting
zone. (Day zone and Fire zones)
4
=
On: if configuration group is a
Cross Zone
5
=
On: enables
Dialer Delay
zone. (See location 40)
6
=
On: if configuration group will use
swinger shutdown
. (See location 38)
7
=
On: enables
Restore reporting
8
=
On: enables
Listen-In
. (See location 40)
Segment 4
1 =
On: enables zone activity monitor
2 =
On: enables end of line resistor defeat on non-fire/non-keyswitch zones
3 =
On : enables zone to act as request to exit input / disables for alarm
activation
4 =
On: enables zone to act as access entry point (Door Shunt) (*)
5
=
Reserved
6
=
Reserved
7
=
Reserved
8
=
Reserved
Segment 5
1-8 Reserved
(*) Note:
Refer to NX-17xx door control installer manual. Do not enable this segment unless
configured with Door Control.
LOCATION 112 - CONFIGURATION GROUP 2 ALARM EVENT CODE (1 segment, numerical data)
Location 112 contains the event code that is sent for a Contact ID or SIA report. The desired event
code should be chosen from the Table 38 or Table 39 in Appendix 1. The zone ID will be the zone
that is in alarm.
This location is not used for slow speed formats (like 4+2 and 3+1). This location may also contain
the alarm report code for the Robofon format (value 00-99).
LOCATION 113 - CONFIGURATION GROUP 2 CHARACTERISTIC SELECT (5 segments, feature
selection data)
Use the “Configuration Group Characteristic Selections” described in Location 111.
LOCATION 114 - CONFIGURATION GROUP 3 ALARM EVENT CODE (1 segment, numerical data)
Location 114 contains the event code that is sent for a Contact ID or SIA report. The desired event
code should be chosen from the Table 38 or Table 39 in Appendix 1. The zone ID will be the zone
that is in alarm.
This location is not used for slow speed formats (like 4+2 and 3+1). This location may also contain
the alarm report code for the Robofon format (value 00-99).
Summary of Contents for NetworX V3
Page 1: ...NetworX Version 3 Alarm System Installation Manual 1070138 ...
Page 10: ...NetworX Version 3 Installation Manual 10 Section A Installing and programming a basic system ...
Page 50: ...NetworX Version 3 Installation Manual 50 Section B Programming the system ...
Page 257: ...NetworX Version 3 Installation Manual 257 Section C References ...