NetworX Version 3 Installation Manual
156
The
Enter Zone No.
prompt displays. Type the zone number and press OK. Repeat this action
for subsequent zones you want to bypass. To remove a zone from the bypassed zone set
enter its number again. To partarm the system with the selected zones bypassed, enter the
user code. Disarming the system clears the bypassed zone set.
Group Bypass
Automatically bypasses all the zones with the
Group Bypass
attribute set (for example,
Interior Follower with Group Bypass Enabled
zone type). It is a shortcut for the
User
Menu>Group Bypass
menu option. To cancel Group Bypass function press the button again.
To partially arm the system with the selected zones bypassed, enter the user code.
Disarming the system clears the bypassed zone set.
Light Control
Allows to turn on or off the X-10 devices connected to the system. It is a shortcut for the
User Menu>Light Control
menu option.
Alarm Memory
Displays the alarm memory list. It is a shortcut for the
User Menu>Alarm Memory
menu
option. The way the list of alarms is displayed depends also on a setting of the First Alarm
Logic menu option (see First Alarm Logic).
Service Check
Performs the service check. It is a shortcut for the
User Menu>Service Check
menu option.
Detector Reset
Resets all the detectors. It is a shortcut for the
User Menu>Detector Reset
menu option.
Answer U/D Call
Answers an upload/download call. It is a shortcut for the
User Menu>Download>Answer U/D
Call
menu option.
Begin U/D Call
Starts an upload/download call. It is a shortcut for the
User Menu>Download>Begin U/D Call
menu option.
Silent Exit
Prevents the exit time buzzer activating when the system is armed or during the re-exit
time. It is a shortcut for the
User Menu>Silent Exit
menu option. This function also doubles
the exit delay (for example, if exit delay is set to 30 seconds, it changes to 60 seconds).
Chime
Toggles the Chime mode off and on (there is a chime icon displayed to indicate the mode
selected) for the Chime type zones. A chime is often used as an indication on a shop door.
There is a beep on chime activation and no beep on deactivation.
Panic Keypad
Starts the panic alarm, which can be cancelled by entering the user code. Depending on the
partition settings, the panic alarm can be silent or audible (see
Emergency Keys, Silent PA,
Audible PA, Speaker Lockout
menu option descriptions in the glossaries). The alarm is
reported and is listed in the event log.
Note:
When you press the panic key and
This keypad>Keypad Features>Beep on Panics
option is disabled, no keystroke sound is emitted.
Medical (Aux2)
Starts the medical alarm, which can be cancelled by entering the user code. The alarm is
reported and is listed in the event log. For the function to work, the
Medical/Aux 2
menu
option must be set for the partition. Depending on the
Emergency Keys
menu option setting,
this alarm can be silent or audible.
Fire Alarm
Starts the fire alarm, which is always audible. The alarm is reported and is listed in the event
log. For the function to work, the
Fire/Aux 2
menu option must be set for the partition.
Phone Number
Allows the user to enter up to three telephone numbers to which events are reported by the
control panel. It is a shortcut for the
User Menu>Phone Numbers
menu option. For the
function to work, the
User Phone Editing
menu option must be enabled, and the voice
protocol must be set for reporting. Voice protocols typically report to the homeowner’s
mobile phone rather than to the central station.
The
Phone No.
prompt displays. Type the telephone ID (1 to 3) and press OK. The
Enter Phone
No.
prompt displays. Type the telephone number the way it should be dialled by the
communicator (including the all necessary prefixes) and press OK.
Arm Night Mode
Arms the system in Night mode. Arming with the function key will report as User 98.
Note:
This shortcut works only if the Quick Arm menu option was set. For this mode to work
correctly, entry guard zones must be set. It works differently in the master mode and in the
single-partition mode. For more information on this button behavior, see the
Master Keypad
,
and the
Quick Arm
menu option description in the glossary.
Cancel
Pressing the Cancel button stops sending reports to the central station.
Info Key
This function displays the Custom Message on the LCD screen. Displaying is finished after
OK or No key is pressed.
Summary of Contents for NetworX V3
Page 1: ...NetworX Version 3 Alarm System Installation Manual 1070138 ...
Page 10: ...NetworX Version 3 Installation Manual 10 Section A Installing and programming a basic system ...
Page 50: ...NetworX Version 3 Installation Manual 50 Section B Programming the system ...
Page 257: ...NetworX Version 3 Installation Manual 257 Section C References ...