NetworX Version 3 Installation Manual
113
Table 17.
Auxiliary output event selection
Data
Event
Data
Event
0
Burglary alarm
30
Open period
1
Fire alarm
31
Closed period
2
24 hour alarm
32
Listen-in
3
Trouble alarm
33
Line seizure
4 Tamper
alarm
34 Reserved
5
Yelping siren
35
Fail to communicate
6
Steady siren
36
Telephone line fault
7
Any siren
37
Program mode
8
Any bypass
38
Download in process
9 AC
fail
39 Reserved
10
Low battery
40
Short circuit (overcurrent on 12 V DC)
11 Duress
41 Box
tamper
12
Aux 1 keypad (fire alarm)
42
Siren tamper
13
Aux 2 keypad (medical alarm)
43
Any open
14
Panic keypad
44
Any short
15
Keypad tamper
45
Any fault (open/short on non-fire zone)
16 Autotest
46 Any
alarm
17
Alarm memory (solid)
47
Beeping keypad
18 Entry
48
♦
Code entry (see note below)
19 Exit
49
♣
Key FOB function 1
20 Entry
or
exit
50
♣
Key FOB function 2
21
Armed state
51
Always ON
22
Disarmed state
52
Autoarm warning time
23
Ready
53
Any siren when in away mode
24
Not ready
54
Progress of entry/exit (follows keypad
buzzer)
25
Fire
55
Auxiliary communication failure
26
Fire trouble
56
Radio test
27
Chime
57
Any siren when armed in any mode
28
Expander trouble
58
Alarm memory (pulsating)
29
Dynamic battery test time
59
Zone inactivity
Notes:
♦
When event 48 is programmed, it is possible to program a user code authorisation to select the
output(s), which a particular code will activate.
♣
Events 49 and 50 require one or more of the following to operate: wireless receivers or
cardreaders.
If set to follow condition, these events will be 1 second.
Setup for auto-test, auto-arm and opening/closing times
LOCATION 51 - AUTOTEST CONTROL (4 segments, numerical data)
Segment 1
Program a “1” if the interval is to be in hours; program a “0” for days. Add a “2” to
suppress the daily test or a “3” to suppress the hourly test if any report has been
sent
Segment 2
Program the autotest interval from 1-255 hours/days
Segment 3
Program the autotest report hour in 24 hour format (if the interval is in hours, this
segment Is ignored)
Segment 4
Program the autotest report time, number of minutes after the hour
Summary of Contents for NetworX V3
Page 1: ...NetworX Version 3 Alarm System Installation Manual 1070138 ...
Page 10: ...NetworX Version 3 Installation Manual 10 Section A Installing and programming a basic system ...
Page 50: ...NetworX Version 3 Installation Manual 50 Section B Programming the system ...
Page 257: ...NetworX Version 3 Installation Manual 257 Section C References ...