NetworX Version 3 Installation Manual
57
4.
The keypad beeps once to confirm the change and returns to
24-hour
.
5.
Scroll to
Attributes>Swinger Zone>Yes
and press
OK
.
6.
The keypad beeps once to confirm the change and returns to
Swinger Zone
.
7.
Set the value of
Inputs>Swinger Count
to 5. For more information see
Setting swinger
count
below.
Setting swinger count
The swinger shutdown function allows the selected zone to be automatically bypassed after a
specified number of alarms. To configure swinger count, you must enable the advanced menu. The
following example sets swinger count to 5. This means that any zone for which swinger shutdown is
enabled can be activated five times within one arm period before it is automatically bypassed.
Bypassing a swinger zone also resets the counter for that zone to zero.