NetworX Version 3 Installation Manual
217
Term
Definition
Account Code
A
Reporting
setting that configures the SIA or Contact ID account number for the selected report
receiver. SIA account numbers are 6 digits long. Contact ID account numbers are 4 digits long. The
letters A, B, C, D, E and F can be included in account codes.
Alarm Restores
A
Reporting
setting that sends a report to the selected report control when the alarm has been
restored after an alarm.
Alarms
A
Reporting
setting that sends a report to the selected report control when an alarm occurs.
All abort
A
Control Panel
menu entry that cancels all pending reports if the system is disarmed during
reporting.
Allow Calls From
An
Up/download
setting that answers calls from a known phone number only. To enable this setting,
you must enable
Remote Initiated
and program the phone number of the PC in
Up/Download>Phone
Number.
Any Phone Access
A
Reporting
menu entry that lists all the users with rights to send HomeText commands from the
phone unknown to the system.
Note:
Sending a HomeText message from the unknown phone requires adding the phone number
registered for the user and the user password at the beginning of the command. They are used by
the system to confirm the user's identity. For example, type
32444123456 44aa44
status
to send a
status command, where 32444123456 is your telephone number registered in the system, and
44aa44 is your password.
Application
An
Options
menu entry that groups application related status messages.
Arm/Disarm/Alarm
A
Reporting
menu entry that groups the events that are reported to the selected report control.
Auto U/D at Test
Time
An
Up/download
setting that configures the NX-7002 to automatically dial the PC to initiate an
upload/download session after an autotest. You must program the autotest on the control panel.
Auto-answer
An
Up/download
setting that configures the NX-7002 to automatically answer any incoming calls. To
enable this setting, you must enable
Remote Initiated
.
Aux Short Circuit and
Restores
A
Reporting
setting that sends a report to the selected report control when too much current is
detected. A restore report is also sent when the overcurrent condition is fixed.
B
Backup Destination
A
Reporting
setting that configures the backup destination for the selected report control. If using
another device as the backup destination, set the reporting format in
Reporting>Backup Format
and
enable test report events in the backup device.
Backup Format
A
Reporting
setting that configures the reporting format when using another device as backup. You
must set the same reporting format on the backup device.
Battery Fault
An
Options
setting that indicates that there is a problem with the battery.
Bit Error Rate
An
Options
setting that displays the current Bit Error Rate (BER). The BER value is periodically updated
when the NX-7002 is logged into the network. This information is used for verification purposes only.
BER values range from 0% to 7%, with 99 as unknown. It is applicable to GPRS only.
Bus Power Fault
An
Options
setting that indicates that there is a problem with power to the bus.
C
Callback Required
An
Up/download
setting that configures the NX-7002 to call back the PC in order to initiate an
upload/download session. To enable this setting, you must enable
Remote Initiated
.
CID
Contact ID reporting protocol
Communications
A
Reporting
menu entry that groups together the communication events that are reported to the
selected report control.
Summary of Contents for NetworX V3
Page 1: ...NetworX Version 3 Alarm System Installation Manual 1070138 ...
Page 10: ...NetworX Version 3 Installation Manual 10 Section A Installing and programming a basic system ...
Page 50: ...NetworX Version 3 Installation Manual 50 Section B Programming the system ...
Page 257: ...NetworX Version 3 Installation Manual 257 Section C References ...