Figure 2.
NetworX V3 inputs and outputs
4
3
5
6 7
8
DATA
Connect to Data terminal of keypad
and expanders
COM
Power (
−
)
POS (+)
Connect to Positive (+) terminal of
keypad and expanders
AUX PWR+
Power (+)
COM
Connect to negative (
−
) terminal of
keypad and expanders
AUX PWR+
Power (+)
BELL+
Internal bell positive
1
Zone 1 [1]
BELL
−
Internal bell negative
COM
Common (
−
) for zone 1 and zone 2 [1]
AUX PWR+
Power (+)
2
Zone 2 [1]
Relay 1 NC
Relay 1 (normally closed)
3 to 8, COM
Zones 3 to 8 and common terminals [1]
Relay 1 NO
Relay 1 (normally open)
Earth
Ground
Relay 1 C
Relay 1 (common)
T1
House Telephone Tip
Relay 2 NC
Relay 2 (normally closed)
T
Telephone Tip
Relay 2 NO
Relay 2 (normally open)
R
Telephone Ring
Relay 2 C
Relay 2 (common)
R1
House Telephone Ring
[1]
The number of onboard zones differs for particular panel models. Refer to “NetworX V3 technical
specifications” on page 13.