NetworX Version 3 Installation Manual
163
Partition Settings
and
System Settings
groups of the
Control Panel
menu. These settings affect all the
keypads in the system or all the keypads in the partition. For example to cancel the keypad exit
buzzer completely for all the keypads:
1.
Navigate with the
½¾
keys to
Control Panel
and press
OK
.
2.
Scroll to
System Settings>Feature Select>Miscellaneous>Silent Exit Always
.
3.
Use the
½¾
keys to change the status to
Yes
and press
OK
.
4.
The keypad beeps once to accept the change and returns to
Silent Exit Always
.
You can also silence the particular keypad. The following options cancel the exit buzzer and chime
on the current keypad only:
1.
Navigate with the
½¾
keys to
This Keypad
and press
OK
.
2.
Select
Keypad Features>Silent Keypad
and press
OK
.
3.
Use the
½¾
keys to change the status to
Yes
and press
OK
.
4.
The keypad beeps once to accept the change and returns to
Silent Keypad
.
To set advanced buzzer options for the keypad on partition 1, when exit delays are set to 20 seconds
and 10 seconds respectively:
1.
Navigate with the
½¾
keys to
Control Panel
and press
OK
.
2.
Scroll to
Partition Settings>Partition 1>Timers>Exit Time 1
and press
OK
.
3.
Type
20
and press
OK
.
4.
The keypad beeps once to accept the change and returns to
Exit Time 1
.
5.
Scroll to
Partition Settings>Partition 1>Timers>Exit Time 2
and press
OK
.
6.
Type
10
and press
OK
.
7.
The keypad beeps once to accept the change and returns to
Exit Time 2
.
8.
Navigate with the
½¾
keys to
This Keypad
and press
OK
.
9.
Scroll to
Keypad Features>Advanced Options>Buzzer On Exit>Exit Time 1
.
10.
Use the
½¾
keys to change the status to enabled and press
OK
.
11.
The keypad beeps once to accept the change and returns to
Exit Time 1
.
12.
Scroll to
Keypad Features>Advanced Options>Buzzer On Exit>Exit Time 2
.
13.
Use the
½¾
keys to change the status to disabled and press
OK
.
14.
The keypad beeps once to accept the change and returns to
Exit Time 2
.
This setting will cancel the final confirmation beep at the end of the exit time, and cause the keypad
to beep slowly for the first 10 seconds and then to beep fast for the last 10 seconds of the exit delay
countdown.
Note:
This option works for the Arm Away mode only; for the Arm Stay mode the keypad is always silent.
The keypad buzzer behaviour depends on both
Buzzer On Exit>Exit Time 1
and
Buzzer On Exit>Exit
Time 2
settings, and is described in the following table:
Summary of Contents for NetworX V3
Page 1: ...NetworX Version 3 Alarm System Installation Manual 1070138 ...
Page 10: ...NetworX Version 3 Installation Manual 10 Section A Installing and programming a basic system ...
Page 50: ...NetworX Version 3 Installation Manual 50 Section B Programming the system ...
Page 257: ...NetworX Version 3 Installation Manual 257 Section C References ...