Configuring the NX-1048 keypad features
General options
You can configure the LCD display, the keypad sounder and combination keys. The following
example configures the keypad so that all codes are displayed as stars rather than in digits. It also
configures the keypad sounder to beep when a wireless receiver does not report within the
supervision window.
1.
Navigate with the
½¾
keys to
This Keypad>Keypad Features
and press
OK
.
2.
Scroll to
Display>Hide PINs>Yes
and press
OK
.
3.
The keypad beeps once to confirm the change and returns to
Hide PINs
.
4.
Navigate with the
½¾
keys to
Beep on RF loss>Yes
and press
OK
.
5.
The keypad beeps once to confirm the change and returns to
Beep on RF loss
.
You can also configure the keypad to hide system status. This is a system-wide option. It causes all
keypads to display a "Please Enter Your Code" prompt, power-on icon and "NOT OK to arm" icon
only, after 30 seconds of keypad inactivity. There is also an option to display time and date instead of
this prompt. In order to operate a blanked keypad you have to enter your user code (both in armed
and disarmed state).
1.
Navigate with the
½¾
keys to
Control Panel>System Settings>Feature
Select>Miscellaneous>KP Shutdown Mode
and press
OK
.
2.
Scroll to
Enabled
and press
OK
.
3.
The keypad beeps once to confirm the change and returns to
KP Shutdown Mode
.
4.
In order to display time and date instead of the "Please Enter Your Code" prompt,
navigate with the
½¾
keys to
This Keypad>Keypad Features>Advanced Options>KP
Shutdown shows Clock>Enabled
and press
OK
.
5.
The keypad beeps once to confirm the change and returns to
KP Shutdown shows Clock
There is an additional option to disarm the system directly from the blanked state, without "waking it
up" first, i.e. avoiding the necessity to enter the user code twice.
1.
Navigate with the
½¾
keys to
This Keypad>Keypad Features>Advanced Options
and
press
OK
.
2.
Scroll to
KP Shutdown allows Disarm>Enabled
and press
OK
.
3.
The keypad beeps once to confirm the change and returns to
KP Shutdown allows
Disarm
.
Programming the function keys
The NX-1048 keypad has 8 function keys F1 to F8. The keys F1, F2, F7 and F8 can be configured to
perform any action listed in the Table 19
Available function key actions
. The other function keys -
F3, F4, F5 and F6 - have a permanent assigned function and cannot be configured. This way you can
create shortcuts for actions that otherwise require selecting a number of the user menu options or
Summary of Contents for NetworX V3
Page 1: ...NetworX Version 3 Alarm System Installation Manual 1070138 ...
Page 10: ...NetworX Version 3 Installation Manual 10 Section A Installing and programming a basic system ...
Page 50: ...NetworX Version 3 Installation Manual 50 Section B Programming the system ...
Page 257: ...NetworX Version 3 Installation Manual 257 Section C References ...