Event logs
In the EN 50131-compliant system two event logs are created - one containing all events, and the
other containing events that are mandatory to log according to the norm (see Table 52).
In order to access the full log, select from the menu
User Menu>Log review
. To access the
mandatory log, select from the menu
User Menu>Mandatory log review
.
Events in the mandatory log are limited to three the same events from the same source in one
arm/disarm cycle. If the event from one source was stored in mandatory log 3 times during one cycle,
next identical events are not stored in the mandatory event log.
The f
ollowing table contains list of all events available in
the
NetworX V3 system, with numbers
and their original names. Events marked with X are mandatory. All other events are non-mandatory.
Table 52.
Mandatory and non-mandatory events
Event number
Event name
Mandatory
0
ALARM
X
1
ALARM RESTORE
X
2
BYPASS
X
3
BYPASS RESTORE
X
4
TAMPER
X
5
TAMPER RESTORE
X
6
TROUBLE
7
TROUBLE RESTORE
8
TX LOW BATTERY
X
9
TX LOW BATTERY RESTORE
X
10
ZONE LOST
X
11
ZONE LOST RESTORE
X
12
START OF CROSS TIME
13 RESERVED
14 RESERVED
15
ZONE INACTIVE
16
ZONE INACTIVE RESTORE
17
SPECIAL EXPANSION EVENT- ELC_EXPANSION_EVENT_TYPE
18
DURESS
X
19
MANUAL FIRE
20
AUXILLARY 2 PANIC
21
B-ALARM
X
22
PANIC
X
23
KEYPRESS TAMPER
X
24
CONTROL BOX TAMPER
X
25
CONTROL BOX TAMPER EVENT
X
26
AC FAIL
27
AC FAIL RESTORE
28
LOW BATTERY
X
Summary of Contents for NetworX V3