NetworX Version 3 Installation Manual
49
Level 1
Level 2
Value
State
Protocol
Phone Number 1
SIA
Phone Number 2
SIA
Events
Phone Number 1 – Alarms
Enabled
Phone Number 1 – Alarm Restores
Enabled
Phone Number 1 – Tampers and Restores
Enabled
Phone Number 2 – Alarms
Enabled
Phone Number 2 – Alarm Restores
Enabled
Phone Number 2 – Tampers and Restores
Enabled
Split reporting
Split reporting configures the control panel to report to two different central stations. Some events
must be reported to phone number 1 and others to phone number 2. The control panel dials the first
number twice. If it cannot reach this number, it dials the second number twice. It performs this
sequence for the number of times specified in
Dial Attempts
or until it reports the relevant event to
each number. The same account code is used to report to both numbers. Events for phone number 1
are enabled by default and events for phone numbers 2 are disabled by default.
Table 14.
Split reporting
Level 1
Level 2
Value
State
Phone Number
Phone Number 1
123456
Phone Number 2
456789
Account Code
Phone Number 1
BE5566
Phone Number 2
445566
Protocol
Phone Number 1
SIA
Phone Number 2
SIA
Events
Phone Number 1 – Alarms
Enabled
Phone Number 1 – Alarm Restores
Enabled
Phone Number 1 – Tampers
Disabled
Phone Number 2 – Alarms
Disabled
Phone Number 2 – Alarm Restores
Disabled
Phone Number 2 – Tampers and
Restores
Enabled
Summary of Contents for NetworX V3
Page 1: ...NetworX Version 3 Alarm System Installation Manual 1070138 ...
Page 10: ...NetworX Version 3 Installation Manual 10 Section A Installing and programming a basic system ...
Page 50: ...NetworX Version 3 Installation Manual 50 Section B Programming the system ...
Page 257: ...NetworX Version 3 Installation Manual 257 Section C References ...