B-44
F60 Feeder Protection System
GE Multilin
B.4 MEMORY MAPPING
APPENDIX B
B
Digital Counter (Read/Write Setting) (8 modules)
A800
Digital Counter 1 Function
0 to 1
---
1
F102
0 (Disabled)
A801
Digital Counter 1 Name
---
---
---
F205
“Counter 1"
A807
Digital Counter 1 Units
---
---
---
F206
(none)
A80A
Digital Counter 1 Block
0 to 65535
---
1
F300
0
A80B
Digital Counter 1 Up
0 to 65535
---
1
F300
0
A80C
Digital Counter 1 Down
0 to 65535
---
1
F300
0
A80D
Digital Counter 1 Preset
–2147483647 to
2147483647
---
1
F004
0
A80F
Digital Counter 1 Compare
–2147483647 to
2147483647
---
1
F004
0
A811
Digital Counter 1 Reset
0 to 65535
---
1
F300
0
A812
Digital Counter 1 Freeze/Reset
0 to 65535
---
1
F300
0
A813
Digital Counter 1 Freeze/Count
0 to 65535
---
1
F300
0
A814
Digital Counter 1 Set To Preset
0 to 65535
---
1
F300
0
A815
Reserved (11 items)
---
---
---
F001
0
A820
...Repeated for Digital Counter 2
A840
...Repeated for Digital Counter 3
A860
...Repeated for Digital Counter 4
A880
...Repeated for Digital Counter 5
A8A0
...Repeated for Digital Counter 6
A8C0
...Repeated for Digital Counter 7
A8E0
...Repeated for Digital Counter 8
Frequency Rate of Change (Read/Write Setting) (4 modules)
A900
Frequency Rate of Change 1 Function
0 to 1
---
1
F102
0 (Disabled)
A901
Frequency Rate of Change 1 OC Supervision
0 to 30
pu
0.001
F001
200
A902
Frequency Rate of Change 1 Min
20 to 80
Hz
0.01
F001
4500
A903
Frequency Rate of Change 1 Max
20 to 80
Hz
0.01
F001
6500
A904
Frequency Rate of Change 1 Pickup Delay
0 to 65.535
s
0.001
F001
0
A905
Frequency Rate of Change 1 Reset Delay
0 to 65.535
s
0.001
F001
0
A906
Frequency Rate of Change 1 Block
0 to 65535
---
1
F300
0
A907
Frequency Rate of Change 1 Target
0 to 2
---
1
F109
0 (Self-reset)
A908
Frequency Rate of Change 1 Events
0 to 1
---
1
F102
0 (Disabled)
A909
Frequency Rate of Change 1 Source
0 to 5
---
1
F167
0 (SRC 1)
A90A
Frequency Rate of Change 1 Trend
0 to 2
---
1
F224
0 (Increasing)
A90B
Frequency Rate of Change 1 Pickup
0.1 to 15
Hz/s
0.01
F001
50
A90C
Frequency Rate of Change 1 OV Supervision
0.1 to 3
pu
0.001
F001
700
A90D
Frequency Rate of Change 1 Reserved (3 items)
0 to 1
---
1
F001
0
A910
...Repeated for Frequency Rate of Change 2
A920
...Repeated for Frequency Rate of Change 3
A930
...Repeated for Frequency Rate of Change 4
IEC 61850 received analog settings (read/write)
AA00
IEC 61850 GOOSE analog 1 default value
–1000000 to 1000000
---
0.001
F060
1000
AA02
IEC 61850 GOOSE analog input 1 mode
0 to 1
---
1
F491
0 (Default Value)
AA03
IEC 61850 GOOSE analog input 1 units
---
---
---
F207
(none)
AA05
IEC 61850 GOOSE analog input 1 per-unit base
0 to 999999999.999
---
0.001
F060
1
AA07
...Repeated for IEC 61850 GOOSE analog input 2
AA0E
...Repeated for IEC 61850 GOOSE analog input 3
AA15
...Repeated for IEC 61850 GOOSE analog input 4
AA1C
...Repeated for IEC 61850 GOOSE analog input 5
AA23
...Repeated for IEC 61850 GOOSE analog input 6
AA2A
...Repeated for IEC 61850 GOOSE analog input 7
AA31
...Repeated for IEC 61850 GOOSE analog input 8
AA38
...Repeated for IEC 61850 GOOSE analog input 9
AA3F
...Repeated for IEC 61850 GOOSE analog input 10
Table B–9: MODBUS MEMORY MAP (Sheet 36 of 53)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for F60 UR Series
Page 2: ......
Page 4: ......
Page 30: ...1 20 F60 Feeder Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 48: ...2 18 F60 Feeder Protection System GE Multilin 2 2 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2 ...
Page 126: ...4 30 F60 Feeder Protection System GE Multilin 4 2 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 354: ...5 228 F60 Feeder Protection System GE Multilin 5 9 TESTING 5 SETTINGS 5 ...
Page 382: ...6 28 F60 Feeder Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 398: ...8 8 F60 Feeder Protection System GE Multilin 8 2 FAULT LOCATOR 8 THEORY OF OPERATION 8 ...
Page 414: ...A 14 F60 Feeder Protection System GE Multilin A 1 PARAMETER LIST APPENDIXA A ...
Page 492: ...B 78 F60 Feeder Protection System GE Multilin B 4 MEMORY MAPPING APPENDIXB B ...
Page 530: ...D 10 F60 Feeder Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIXD D ...
Page 542: ...E 12 F60 Feeder Protection System GE Multilin E 2 DNP POINT LISTS APPENDIXE E ...
Page 558: ...x F60 Feeder Protection System GE Multilin INDEX ...