– 49 –
Water Valve
Disconnect power to the dryer.
Remove the J8 connector. Check resistance between the J8 brown wire to the red wire on the J5 connector.
Should read approximately 550 ohm.
If resistance is good, reconnect wires and put the dryer in service mode. Check for 120 VAC at the same.
L1
N
R-18 B-18
WATER
VALVE
O-18
O-18
O-18
O-18
B-18
J5
1
POWER BOARD
C-18
W-18
R-14
R-18
5
6
4
G
B-18
DRUM MOTOR SHOWN STOPPED
CHASSIS
BASE
GY-14
S-20
S-20
IDLER
SWITCH
C-18
DOOR SWITCH
SHOWN
DOOR CLOSED
(NOT USED)
C-18
C-18
W-18
W-18
R-14
TO OUTLET
CONTROL BACKUP
J8
1
(533-590 )
R-18
P-18
3
NC
NO
COM