– 27 –
Drum Motor
The drum motor is a single-speed, 120 VAC, 1/3
hp, 5.0 amp rated motor with an automatic reset
overload protector. The overload protector is an
internal component of the motor and cannot
be replaced separately. The motor contains a
centrifugal switch that serves two purposes:
• Disengages the motor start winding.
• Closes the circuit contacts for the heat source.
The switch is an internal component of the motor
and cannot be replaced separately.
Drum Motor Removal
1. Remove the drum. (See Drum Removal in this
guide.)
2. Unlock the idler arm from the idler arm bracket.
3. Disconnect the motor wire harness.
Non-Long Vent Model
Long Vent Model
4. On non-long vent models, remove the blower
wheel (see the Blower Wheel Removal section
in this guide.)
5.
8VLQJDÀDWEODGHVFUHZGULYHUFRPSUHVVDQG
then remove the front and rear motor straps
from the motor bracket.
6. Lift the motor from the motor bracket.
Non-Long Vent Model
Long Vent Model
Idler Arm
Disconnect
Idler Arm
Disconnect
Motor Strap
Motor Strap
Motor Strap
Motor Strap