– 30 –
Gas Valve Coils
The burner assembly gas valve utilizes two coils. A
double coil (safety and booster coils combined) and
a single main coil are located on top of the gas valve
in front of the combustion chamber opening. The
coils can be replaced separately.
Gas Valve Coil Assembly Resistance Values:
•
6DIHW\FRLOWHUPLQDOV
•
%RRVWHUFRLOWHUPLQDOV
•
0DLQFRLOWHUPLQDOV
To remove the double and main coils:
1. Remove the burner assembly from the dryer.
(See the Gas Valve Removal section in this
guide, and follow steps 1 through 7.)
2. Note the position of the locator pins inserted in
the coil bracket.
3. Remove the two Phillips head screws that attach
the coil bracket to the valve body.
4. Lift the coil bracket vertically.
5. Lift coils vertically from valve assembly.
NOTE: Upon assembly, ensure the locator pins are
inserted into the holes provided in the coil bracket.
Main Coil
Booster Coil
Safety Coil
Coil Bracket
Locator Pin
Locator Pin