– 31 –
Ignitor
WARNING: Sharp edges may be exposed when
servicing the dryer. Use caution to avoid injury. Wear
Kevlar® gloves or equivalent protection.
The ignitor is located at the end of the burner
assembly in the combustion chamber opening and
has a maximum rating of 4 amps. The ignitor has an
DSSUR[LPDWHUHVLVWDQFHYDOXHRIWRű
The ignitor is attached to the gas valve bracket
with a Phillips head screw. To access the ignitor, it is
necessary to remove the burner assembly. (See the
Gas Valve Removal section in this guide and follow
steps 1 through 7.)
NOTE: When installing the ignitor, make sure the
ignitor wiring harness is routed through the opening
in the burner bracket.
CAUTION: The ignitor is very fragile. To prevent
breaking the ignitor, care must be taken when
installing the burner assembly.
Flame Detector
7KHÀDPHGHWHFWRULVDWWDFKHGWRWKHULJKWVLGHRI
the combustion chamber.
Flame Detector Removal
1. Remove the front bulkhead. (See Front Bulkhead
Removal in this guide.)
2.
'LVFRQQHFWWKHWZRZLUHVIURPWKHÀDPH
detector.
3.
5HPRYHWKHÀDPHGHWHFWRUIURPWKHWDEDWWKH
bottom.
NOTE: Upon reassembly, ensure the tab at the
ERWWRPRIWKHÀDPHGHWHFWRULVLQVHUWHGLQWRWKHVORW
located on the combustion chamber.
Gas Valve Bracket
Harness Opening
Ignitor Harness
Tab