36
—
Operating Procedures / Photos
Disassemble Capillary
Unsolder the soldering points at the capillary, the valve
and the condenser to remove the capillary. Pay attention
not to allow the soldering slag to block the capillary.
(refer to Figure 8-34)
Disassemble Valve
Unscrew the two screws fixing the gas valve, unsolder the
soldering point between the gas valve and the return-air
duct and remove the gas valve.
(Note: when unsoldering the soldering point, use wet cloth
to completely wrap the gas valve to prevent valve body
from being harmed by high temperature).
Unscrew the two screws fixing the liquid valve, unsolder
the soldering point connecting the liquid valve and the fork
type pipe, and remove the liquid valve.
(refer to Figure 8-35)
Disassemble Compressor
Firstly unsolder the pipes connecting the compressor, and
then unscrew the three foot nuts at the compressor to
remove the compressor.
(refer to Figure 8-36)
Capillary
Figure 8-34
Liquid Valve
Screw
Gas Valve
Figure 8-35
Foot Nut
Figure 8-36