Test Run
1. Preparation of Test Run
①
Do not switch on the power before all installation work is completed.
②
Confirm that the control line is correctly installed and all electrical lines are firmly connected.
③
Open the shutoff valves of the big and small pipes.
④
Remove all foreign articles, especially metal scraps, line ends and forceps, from the unit.
2. Method of Test Run
①
Connect to the power supply, press the
“
ON/OFF
”
key to start test run.
②
Press the Mode key, select the operating modes such as cooling and fan, and observe if the operation is normal.
3. Emergency Operation :
In case the remote controller is lost, carry out the following operation :
* When the unit is stopped, press the Auto switch on the corner outer cover
Ⅱ
, then the unit shall start auto operation. The
microprocessor shall automatically select cooling, heating or dehumidifying according to the room temperature to reach a
comfortable effect.
* When the unit is in operation, press the Auto switch on the corner outer cover
Ⅱ
, then the unit stops operation (the
outdoor unit shall stop operation at the same time).
Caution :
The test switch on the corner outer cover
Ⅱ
is specially for test run. When pressing this key, the air-conditioning unit carries
out compulsory running without subjecting to the limit of temperature.
Do not use this key when the air-conditioning unit is in normal operation!
Single Phase
3-Phase
Cooling Only Type
Heating and Cooling Type
3-Core Rubber Covered
Cable (Connecting to
Power Supply)
3-Core Rubber
Covered Cable
(Connecting to Room)
5-Core Rubber Covered
Cable (Connecting to
Electric Network Power
Source)
5-Core Rubber Covered
Cable (Connecting to
Indoor Unit)
5-Core Rubber Covered
Cable (Connecting to
Electric Network Power
Source)
Front Plate
Terminal Board
Rear Side Plate
Outdoor Cable-Cross Hole
Cable
(Connecting to Room)
(Connecting to Power Supply)
Electrical Connection Diagram of
Communication Cassette Type Unit
(Figure 11)
Summary of Contents for AIR C18
Page 2: ......
Page 3: ......
Page 5: ... 2 Model Remarks GE AIR C24 Communication Ceiling Mounted Unit 1PH 230V 50Hz R407C ...
Page 14: ... 11 Applicable to GE AIR C24 OUT Unit mm Over 600 Bolt Nut Wrench ...
Page 15: ... 12 Applicable to GE AIR C34 C41 OUT 378 Unit mm Over 600 Bolt Nut Wrench ...
Page 17: ... 14 Electrical Diagram GE AIR C18 GE AIR C24 6 ...