![background image](http://html.mh-extra.com/html/ge/air-c18/air-c18_service-manual-installation_122415038.webp)
—
35
—
Operating Procedures / Photos
Disassemble Axial Flow Fan
Use spanner to remove the nut at the fan to
remove the axial flow fan.
(refer to Figure 8-31)
Disassemble Outdoor Motor
Screw off the four tapping screws fixing the
motor, pull out the motor lead-out cable plug, and
remove the motor. Screw off the two tapping
screws fixing the motor support, and pull the
motor support upward to remove it.
(refer to Figure 8-32)
Disassemble 4-Way Valve
Screw off the holding nut of the 4-way valve coil
and remove the coil. Use wet cotton cloth to wrap
the 4-way valve, unsolder the four soldering
points connecting the 4-way valve, and remove
the 4-way valve. Be quick during the unsoldering
process, pay attention to keep the wrapping cloth
wet and do not allow the soldering flame to burn
the compressor lead-out cable.
(refer to Figure 8-33)
Screw
Axial Flow Fan
Figure 8-31
Motor
Screw Fixing
the Motor
Motor Cable
Motor Support
Fixing Screw
Figure 8-32
4-Way Valve
Soldering Point
Figure 8-33
Summary of Contents for AIR C18
Page 2: ......
Page 3: ......
Page 5: ... 2 Model Remarks GE AIR C24 Communication Ceiling Mounted Unit 1PH 230V 50Hz R407C ...
Page 14: ... 11 Applicable to GE AIR C24 OUT Unit mm Over 600 Bolt Nut Wrench ...
Page 15: ... 12 Applicable to GE AIR C34 C41 OUT 378 Unit mm Over 600 Bolt Nut Wrench ...
Page 17: ... 14 Electrical Diagram GE AIR C18 GE AIR C24 6 ...