26
—
Operating Procedures / Photos
Disassemble Pump Drainage Pipe
Use wire cutter to cut the cable bundle, separate the pump drainage pipe and the pump water outlet, use
screwdriver to screw off the two screws beside the drainage pipe, then pull the pump drainage pipe
outward to remove it. (refer to Figure 8-10 and 8-11)
Disassemble Pump Assy,
Pump and Water Level Switch
Use socket wrench to twist off the nut beside
the pump assy, and then manually pull the
pump assy upward to remove it.
Use screwdriver to screw off the four screws
beside the pump.
Use screwdriver to screw off the two screws
beside the water level switch. (refer to Figure
8-12, 8-13 and 8-14)
Liquid Level Switch
Pump
Pump Drainage Pipe
Figure 8-10
Screw
Figure 8-11
Nut with Washer
Figure 8-12
Screw
Pump
Screw
Water Level
Switch
Screw
Figure 8-13
Figure 8-14
Summary of Contents for AIR C18
Page 2: ......
Page 3: ......
Page 5: ... 2 Model Remarks GE AIR C24 Communication Ceiling Mounted Unit 1PH 230V 50Hz R407C ...
Page 14: ... 11 Applicable to GE AIR C24 OUT Unit mm Over 600 Bolt Nut Wrench ...
Page 15: ... 12 Applicable to GE AIR C34 C41 OUT 378 Unit mm Over 600 Bolt Nut Wrench ...
Page 17: ... 14 Electrical Diagram GE AIR C18 GE AIR C24 6 ...