Defrosting is incomplete
Replace defrosting temp. sensor
Insufficient flow through pipeline valve
Fully open the valve
Insufficient refrigerant
Find out leakage point and charge refrigerant
Poor thermal insulation of refrigerant
connecting pipe between outdoor unit
and indoor unit
Big pipe and small pipe shall have separate
thermal insulation
Do not install it directly at steel window
Install it on thick wall with certain strength
Indoor unit is installed on wallboard or thin
wall panel so noise is caused owing to
resonance
Take proper vibration damping measures
Pipes of outdoor unit bump together
Adjust fan motor position
Foreign articles inside the indoor unit
Remove foreign articles
Vibration of compressor is violent
Adjust support foot mat of compressor, tighten
oose bolts
Pipes of outdoor unit bump together
Separate bumping pipes
Tighten connection screws
Metal plates bump together inside the unit
Attach vibration damping gum between metal
plates
Indoor fan bumps cabinet
Adjust fan position
Abnormal sound from inside compressor
Replace Compressor
Abnormal electromagnetic noise from
4-way valve when in heating operation
Internal short circuit of solenoid valve, replace
solenoid valve
Abnormal
so
und
a
nd
v
ib
ra
ti
o
n
Summary of Contents for AIR C18
Page 2: ......
Page 3: ......
Page 5: ... 2 Model Remarks GE AIR C24 Communication Ceiling Mounted Unit 1PH 230V 50Hz R407C ...
Page 14: ... 11 Applicable to GE AIR C24 OUT Unit mm Over 600 Bolt Nut Wrench ...
Page 15: ... 12 Applicable to GE AIR C34 C41 OUT 378 Unit mm Over 600 Bolt Nut Wrench ...
Page 17: ... 14 Electrical Diagram GE AIR C18 GE AIR C24 6 ...