38
—
Operating Procedures / Photos
Disassemble housing
Unscrew the screws around the
housing to remove it.
(refer to Figure 8-39)
Disassemble Electric Box
Unscrew the screws around the
electric box sub-assy to remove the electric
box sub-assy.
(refer to Figure 8-40)
Disassemble Right Side Plate
Unscrew the screws around the
right side plate to remove it.
(refer to Figure 8-41)
Screw
Cabinet
Figure 8-39
Screw
Screw
Communication Cassette
Type Unit Electric Box
Figure 8-40
Screw
Right Side Plate
Figure 8-41
Summary of Contents for AIR C18
Page 2: ......
Page 3: ......
Page 5: ... 2 Model Remarks GE AIR C24 Communication Ceiling Mounted Unit 1PH 230V 50Hz R407C ...
Page 14: ... 11 Applicable to GE AIR C24 OUT Unit mm Over 600 Bolt Nut Wrench ...
Page 15: ... 12 Applicable to GE AIR C34 C41 OUT 378 Unit mm Over 600 Bolt Nut Wrench ...
Page 17: ... 14 Electrical Diagram GE AIR C18 GE AIR C24 6 ...