190-01115-01
G3X/G3X Touch Install Manual - GDU 4XX Config and Post Install Checkout
Rev. AC
Page 34-144
34.4.26.8 Oil Temperature
The following sensors can be configured for the Oil Temperature input on the GEA 24 or GSU 73:
•
UMA 1B3-2.5R RTD
•
Rotax 965531
•
Rotax 966385
•
Jabiru VDO 320-021 thermistor
•
MS28034 / MIL-T-7990 RTD
•
Thermistor (any VDO or similar 50-150°C thermistor)
FADEC:
The GEA 24 can be configured to monitor oil temperature data from the following
FADEC interfaces:
•
Rotax (912iS/915iS)
•
Lycoming (iE2)
•
ULPower
34.4.26.9 CHT (Cylinder Head Temperature)
The following sensors can be configured for the CHT inputs on the GEA 24 or GSU 73:
•
Type J thermocouple
•
Type K thermocouple
•
Rotax 965531
•
Rotax 966385
•
Thermistor (any VDO or similar 50-150°C thermistor)
NOTE
For the GEA 24, thermistor CHT sensors (including Rotax CHT sensors) are connected to
different input pins (see Section 31.2)
NOTE
For the GSU 73, thermistor CHT sensors (including Rotax CHT sensors) are connected to
general purpose (GP) input pins (see Section 31.3).
FADEC:
The GEA 24 can be configured to monitor cylinder head temperature data from the
following FADEC interfaces:
•
Lycoming (iE2)
•
ULPower
If two EIS LRUs are configured, up to 6 cylinders may be configured for a twin-engine application, or up
to 12 cylinders for a single engine. In a single-engine application, cylinders 1-6 are connected to CHT 1-6
on EIS LRU #1, and cylinders 7-12 are connected to CHT 1-6 on EIS LRU #2.