G1000 NXi System Maintenance Manual
Page 240
King Air 300 Series
Revision 1
190-00716-N1
Figure 6-3, Configuration Module Installation
Table 6-1, Configuration Module Kit – 011-00979-00
Item
Description
Qty Needed
Garmin Part
Number
1
Configuration Module PCB Board Assembly w/EEPROM & Temp
Sensor
1
012-00605-00 or -02
2
Spacer, Config Module
1
213-00043-00
3
Cable, 4-Conductor Harness
1
325-00122-00
4
Pins, #22 AWG (HD)
5
336-00021-00
Removal:
1. Disconnect connector from LRU.
2. Remove 2 screws (8) from cover (7) and remove cover.
3. Unplug connector from configuration module (1).
4. Remove configuration module.
Installation:
1. Inspect connector for damaged pins (4).
2. Place configuration module (1) in position.
3. Insert connector into configuration module (1).
4. Assembly of the connector is the reverse of disassembly.
5. Checkout per Section 6.17.4.