G1000 NXi System Maintenance Manual
Page 337
King Air 300 Series
Revision 1
190-00716-N1
GSR 56
Original GSR 56 Reinstalled
No software or configuration loading is required if the removed GSR 56 is re-installed. This
does not include units that were returned for repair as their software and configuration files are
deleted during the repair testing process. Continue to the GSR 56 Test Section 7.14.3.
New, Repaired or Exchange GSR 56 Installed
If a new, repaired or exchange GSR 56 is installed, the correct software and configuration files
must be loaded to the unit. See Section 3.6 and then continue to the GSR 56 Test Section
7.14.3.
LRU Replacement Procedure GSR 56
LRU Replacement feature is not available for the GSR56, continue to Section 7.19.2.
Legacy Replacement Procedure GSR 56 (Alternate Method)
1. Insert the software loader card in the top slot of PFD1.
2. Power on PFD2, MFD, and PFD1 in configuration mode.
3. Select
NO
when “Do you want to update system files” is displayed on the screen of
PFD1.
4. Select the “
SYSTEM UPLOAD
” page using the small FMS knob on PFD1.
5. Activate cursor and rotate the small FMS knob to display the drop down menu. Rotate
the small FMS knob to highlight “
07) Connext - SXM”
and press
ENT
key on PFD1.
6. Rotate the small FMS knob to highlight the installed GSR 56 configuration. Press
ENT
key on PFD1.
7. Verify the installed GSR 56 configuration is displayed in the “Item” window.
8. Press the
CHK ALL
key.
9. Press the
Load
softkey.
10. Monitor load progress. Verify software load completes without errors as indicated by the
following:
•
Green “PASS” in the Configuration and Software columns for each item loaded.
•
“Upload Complete………….COMPLETE” in the summary box.
11. Press
ENT
key on PFD1 to acknowledge upload complete.
12. Deactivate cursor.
13. Scroll to the Configuration Manager page.
14. Press the
CNFM CFG
softkey.
15. Select ok when prompted to “Confirm configuration as expected configuration”
16. Power cycle the system. Verify there are no red-Xs or system alerts.
17. If red-Xs or system alerts are present, troubleshoot as necessary using Section 5.
18. If there are no red-Xs or system alerts, continue to Section 7.19.3.