G1000 NXi System Maintenance Manual
Page 96
King Air 300 Series
Revision 1
190-00716-N1
NOTES
•
The V1 value is the start or lower limit of the color bar range and the V2
value is the upper limit.
•
When the
RAD
(radial) TYPE is selected, the V1 and V2 values will be
the same. The installer can only set the V1 value, the V2 value will be
grayed out and unchangeable.
•
When the
FULL
TYPE and
BAR
(barber pole) CLR is selected, V2 will
automatically default to MAX and is unchangeable.
•
For unused rows, the TYPE should be set to
OFF
, the CLR should be set
to
BLU
, and V1 and V2 values should be set to “
000
”.
g. Continue in sequence through all rows to enter the color bands needed and
select
EXIT
when done.
17. In the CONFIGURE AIRCRAFT menu, select
VNE TABLE
.
18.
Enter
the table information below.
300
B300
#
ALT(FT)
KTS
ALT(FT)
KTS
1
00000
259
00000
263
2
21000
259
21000
263
3
25000
239
25000
242
4
30000
214
30000
217
5
35000
191
35000
194
6
UNUSED
000
UNUSED
000
7
UNUSED
000
UNUSED
000
19. Select
EXIT
when done entering the table.
20. Select
EXIT
in the CONFIGURE AIRCRAFT menu.
21. In the CONFIGURE MENU, select
CONFIGURE BARO SYNC
.
22. Select
OFF
.
23. In the CONFIGURE MENU, select
CONFIGURE DIMMING
.
24. Select
DIMMING CONTROL
.
25. Select
EXT 28V
.
26. In the CONFIGURE DIMMING menu, select
DIMMING CURVE
.