G1000 NXi System Maintenance Manual
Page 94
King Air 300 Series
Revision 1
190-00716-N1
3. Verify that the DATA window shows the following:
Hdg: None:
J3-1
Jumper
J3-2
Jumper
Hdg Valid Flag
No Fla
Flag Sense
+invld
J3-4
Open
Hdg Value
<aircraft heading>
Inhibit Line
Off
Antenna Mount
Bottom
J3-3
Open
4. Deactivate the cursor.
NOTE
The DATA window is only updated once every five seconds.
MD 302 Configuration and Sensor Calibration
NOTE
In the MD 302 Configuration Mode, any changes made to any settings will
NOT be saved until you select ACCEPT CHANGES in the menu prior to
exiting the Configuration Mode.
MD 302 Configuration
1.
Open
STBY INSTR circuit breaker.
2.
Press and hold
the MD 302 control knob on the front of the unit.
3.
Close
STBY INSTR circuit breaker.
4.
Release
the control knob when the introduction screen appears.
5. In the CONFIGURE MENU, select
CONFIGURE DISPLAY
by rotating the control knob
to highlight the option and press the control knob to select it.
6. In the CONFIGURE DISPLAY menu, select
AIRSPEED UNITS
.
7. Select
KNOTS
.
8. In the CONFIGURE DISPLAY menu, select
EXIT.
9. In the CONFIGURE MENU, select
CONFIGURE AIRCRAFT
.
10. Select
PANEL TILT
.
Summary of Contents for G1000 NXi