Static Port Vertical Speed (Rate of Climb) Test
1. Command ADTS to change the altitude at the rates shown in the table below.
2. Wait for ADTS to report that target rates have been achieved.
3. Verify that the Rate of Climb reported by the Vertical Speed field on PFD1 and PFD2 are
within the tolerances specified in Table 7-9.
Table 7-9, Vertical Speed Table
Vertical Speed, feet/minute
Allowed tolerance, ±feet/minute
2000
100
1000
50
500
45
200
45
0
N/A (No VS Display)
-200
45
-500
45
-1000
50
-2000
100
OAT Probe Check
1. Ensure on-side sensors for PFD1 and PFD2.
2. Ensure the outside air temperature (OAT) probes and a calibrated thermometer stabilize
at ambient temperature.
3. Verify that the OAT measurement shown on PFD1 and PFD2, in degrees Celsius,
indicate within 2 °C of the ambient temperature as measured by the calibrated
thermometer.
If no other service is to be performed, continue to the return-to-service checks in Section 9.